Mass oil burner / NFPA 31 & NORA
Study online at https://quizlet.com/_a29phk

1. Cast iron fittings can be used in heating fuel False
systems?

2. Tank vent shall terminate Within 12 feet of the fill and visible from
the fill

3. Tanks exceeding 330 gallons must have Top supply connection

4. Fuel return piping from an appliance shall Enter the top of the tank

5. Oil appliances burning used oil shall only be In commercial or industrial occupancies
installed

6. Technician must be present for filling of new False
oil tank

7. A common tank vent pipe shall be One pipe size larger than the largest in-
dividual vent pipe connected to it

8. If oil supply piping is not visible for inspec- Pressure or vacuum test the line
tion you must

9. Installation instructions for the care and op- True
eration of the appliance must be posted

10. Oil burning appliances shall have Limit control for pressure in steam, tem-
perature in water boiler, and tempera-
ture in furnace

11. Above ground tank installed inside must be Torwards the supply at a pitch of 1/4 inch
pitched per foot

12. Outdoor tanks must be located Five feet from property line for 275g or
smaller, ten feet for more than 275 but



, Mass oil burner / NFPA 31 & NORA
Study online at https://quizlet.com/_a29phk

not exceeding 660g. Must be on con-
crete slab

13. A chimney connector shall maintain a pitch 1/4 inch per foot
or rise of

14. Minimal gauge thickness for steel flue pipe 26 gauge
connectors less than nine inches in diameter

15. Oil fired water heater must be equipped with True
water temp, pressure, and vacuum relief de-
vice

16. Tank vent piping shall be Pitched forward tank, terminate two feet
minimum from building openings, cor-
rosion resistant weatherproof cap

17. Direct vent systems shall terminate 4 feet horizontally from a building open-
ing

18. Fuel can be transferred from tank to appli- False
ance by pressurizing the tank

19. Fusible link safety shutoff valves shall be lo- Within six inches of the filter between the
cated tank and filter

20. Before installation of new oil burner you are Inspect the combustion chamber
required to

21. A crankcase oil burner can be installed in False
any location where a standard oil burner was
located

22. Can tanks be installed in garages



, Mass oil burner / NFPA 31 & NORA
Study online at https://quizlet.com/_a29phk

Yes, if protected from vehicle impacts by
barriers

23. Teflon tape can be used on oil lines False

24. The trial for ignition period for oil burners 15 seconds
less than 20 GPM is?

25. Fusible switches shall operate at a temp of 165F

26. A masonry chimney needs a metal liner False

27. Any valves used on oil burner installation Fusible valve
must be a

28. What form is used to pull an oil burner per- Form 1
mit

29. What size pipe is used to cross connect tank 1/2 inch
outlet piping

30. What is an oil safety valve required On existing installations when a burner,
boiler, furnace or tank is replaced

31. When must you install a draft regulator When not exempted by the manufactur-
er

32. As of January 1 2014, max safety timing for 15 seconds
an oil burner safety switch must be no more
than

33. What type of boiler must be equipped with Water boilers over 400,000 BTU, all
low water cut off steam boiler

34. A draft inducer

Información del documento

Subido en
28 de agosto de 2026
Número de páginas
21
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TrustedExaminer
4.0
(9)
Vendido
90
Seguidores
4
Artículos
3796
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.