For ________, the gas supply must be shut off first and then call 911.
Piped gas
When not possible to shut off gas supply, allow the flame to
___________ and call 911.
Burn itself out
Class a extinguishers are for extinguishing ___________.
Ordinary combustibles
Class b extinguishers are for extinguishing ___________.
Flammable or combustible liquids
Class c extinguishers are for extinguishing _____________.
Electrical equipment
Class d extinguishers are for extinguishing ____________.
,Ignitable metals
Fire extinguishers are required to inspected __________.
Monthly
Fire extinguishers must be maintained by a fdny approved company
at least ___________.
Once per year
Certificate of fitness: fire watch for torch operations conducted at
the following three locations shall be conducted by at least one f-60
fire guard
1- construction sites
2-in any building or structure, when the torch operation is conducted
by a person holding a citywide permit for torch operations
3-on any rooftop, or in connection with any torch-applied roofing
system operation
Certificate of fitness holder must...
Keep the certificate of fitness upon his or her person, or otherwise
readily available for inspection by any representative of the
department, at all times while conducting or supervising the
material, operation or facility for which the certificate is required
,The f-60 certificate of fitness holder is required to comply with the
following fdny cod and rules section:
-welding and other hot work
-fire prevention during welding, cutting and other hot work
-liquefied petroleum gases
-compressed natural gasses
Fdny permits 3 of the following
1- storing, using or handling oxygen and a flammable gas, or
2- storing, using or handling any flammable gas in excess of 400 scf
or
3- storing, using or handling any oxidizing gas (ex. Oxygen) in excess
of 504 scf
Lpg - 400 scf is how many pounds?
47 lbs.
List of the number of lpg containers for storage, use, handling or
transportation, requiring a permit
14.1 oz= 54
16.4 oz = 46
20 lbs = 3
33.5 lbs = 2
, 40 lbs = 2
100 lbs = 1
Lpg
Portable lpg containers that are more than 16.4 oz and cng
containers with a capacity greater than 8.7 scf must not stored,
handled, or used indoors/roof in the following occupancies....
-residential areas
-factory and industrial occupancies
-educational occupancies
-institutional occupancies
Except as the commissioner may authorize by rule
Use of lpg/propane on an occupied roof requires...
An affidavit from a licensed professional (architect or engineer)
stating the roof is constructed of non-combustible material(s)
Any single standard lpg must not exceed...
100 lbs in weight
EXAM QUESTIONS |MOST TESTED QUESTIONS AND CORRECT
ANSWERS RATED A+
For ________, the gas supply must be shut off first and then call 911.
Piped gas
When not possible to shut off gas supply, allow the flame to
___________ and call 911.
Burn itself out
Class a extinguishers are for extinguishing ___________.
Ordinary combustibles
Class b extinguishers are for extinguishing ___________.
Flammable or combustible liquids
Class c extinguishers are for extinguishing _____________.
Electrical equipment
Class d extinguishers are for extinguishing ____________.
,Ignitable metals
Fire extinguishers are required to inspected __________.
Monthly
Fire extinguishers must be maintained by a fdny approved company
at least ___________.
Once per year
Certificate of fitness: fire watch for torch operations conducted at
the following three locations shall be conducted by at least one f-60
fire guard
1- construction sites
2-in any building or structure, when the torch operation is conducted
by a person holding a citywide permit for torch operations
3-on any rooftop, or in connection with any torch-applied roofing
system operation
Certificate of fitness holder must...
Keep the certificate of fitness upon his or her person, or otherwise
readily available for inspection by any representative of the
department, at all times while conducting or supervising the
material, operation or facility for which the certificate is required
,The f-60 certificate of fitness holder is required to comply with the
following fdny cod and rules section:
-welding and other hot work
-fire prevention during welding, cutting and other hot work
-liquefied petroleum gases
-compressed natural gasses
Fdny permits 3 of the following
1- storing, using or handling oxygen and a flammable gas, or
2- storing, using or handling any flammable gas in excess of 400 scf
or
3- storing, using or handling any oxidizing gas (ex. Oxygen) in excess
of 504 scf
Lpg - 400 scf is how many pounds?
47 lbs.
List of the number of lpg containers for storage, use, handling or
transportation, requiring a permit
14.1 oz= 54
16.4 oz = 46
20 lbs = 3
33.5 lbs = 2
, 40 lbs = 2
100 lbs = 1
Lpg
Portable lpg containers that are more than 16.4 oz and cng
containers with a capacity greater than 8.7 scf must not stored,
handled, or used indoors/roof in the following occupancies....
-residential areas
-factory and industrial occupancies
-educational occupancies
-institutional occupancies
Except as the commissioner may authorize by rule
Use of lpg/propane on an occupied roof requires...
An affidavit from a licensed professional (architect or engineer)
stating the roof is constructed of non-combustible material(s)
Any single standard lpg must not exceed...
100 lbs in weight