The Most important factor to consider in forcible entry is Select the right tool to do the job
to
When making a large opening in a masonry wall, a ___ Triangular/inverted V
shape should be cut to help maintain structural integrity.
What is the leading cause of firefighter injuries Overexertion and strain
The proper name for one of the structural sides of a Beam
ladder is a
Which of the following is not a requirement for an Being certified as a pumper driver/operator
individual trained in fire suppression?
Which of the following statements regarding power saw The saw should be started at level ground and carried up the ladder while
safety is incorrect running.
during overhaul, if firefighters have concern about a void open the void space immediately
space concealing a "hot spot", they should
The process of dividing large jobs into smaller jobs to division of labor
make them more manageable is described as
Which of the following is not a method for preventing remove wet hose from apparatus and replace with dry hose
mechanical damage to a fire hose?
During an interior structural fire attack, if ventilation holes Straight
cannot be made large enough, or if ventilation will be
delayed, then it is important to keep that nozzle on a ___
stream.
The fire tetrahedron includes all the elements of the fire chemical reaction
triangle plus
Which of the following is an advantage of the flat load? It is the best way to load large diameter hose
Firefighters can expect to find ledge doors in Barns and warehouses
The person that stabilizes the victims of accidents or Fire responder
illnesses until more highly trained medical personnel
arrive is the
The ___ stage occurs when all combustible materials in Fully-developed
the compartment are involved in the fire
After the roof has been opened up, the firefighter must. ensure the ceiling below the cut is opened
, FF1 Study Guide | Firefighter I Exam Questions & Answers
During the ______ stage of fire, the fire frequently Fully-developed
becomes ventilation controlled.
Surface fuels are involved in what type of fire Ground
while working from a ground ladder, the hook on the attached to the rung
firefighters safety harness should be
a stream discharging more that 350 gpm is known as/an Master
____ stream.
What is the first step a firefighter should take because if remain calm and relay on previous training.
their scba becomes damaged or malfunctions
The ratio of a mass of a given volume with liquid specific gravady
compared with the mass of an equal volume of water at
the same temperature is:
A primary safety concern when raising a ladder should possible contact with over head wires and obstruction
be
Which of the following is an advantage of an according Hose for shoulder carries can easily be taken from the load
load.
Hose is unloaded at the scene of a fire and the pumper reverse
proceeds to the water source. This is an example of a
__________ lay.
Fire can be extinguished by reducing heat, removing oxygen, removing fuel, or stopping the chemical chain
reaction.
Compartment fires in the ___ stage are generally Growth
fuel/oxygen controlled.
One of the primary functions of the truck/ladder company performing forcible entry into fire building
is
one disadvantage of positive pressure fans is that they Can spread the fire if used improperly
When cutting through a roof, a firefighter should attempt make the opening square or rectangular.
to:
A relatively new hazard that firefighters must be aware of supplemental restraint systems/airbags
when approaching fires involving
newer model vehicles is:
When descending stairs in a smoke-charged structure, a move downward on hands and knees feet first.
firefighter should: