The minimum size equipment grounding conductor for a 100 ampere, 120/240
volt single phase underground dwelling feeder whose ungrounded conductors
have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG
copper


Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - CORRECT ANSWER-4


The continuity of the grounded conductor shall depend on a busbar or __ only.


Continuity, Grounded conductors
200.12 - CORRECT ANSWER-wire.


Each multi-wire branch circuit shall be provided with a means that will ____
disconnect all ungrounded conductors at the point where the branch circuit
originates.


Disconnecting means, Branch circuits, multiwire 210.4(B) - CORRECT ANSWER-
Simultaneously

,Balconies, decks, and porches that are accessible from the inside of the dwelling
unit shall have at least one receptacle not more than __ ft. above the balcony,
deck, or porch surface.
Balconies, outdoor, receptacles for,
210.52(E)(3) - CORRECT ANSWER-6 1/2


Where it is impracticable to locate the service head above the point of
attachment, the service head location shall be permitted not farther than ___
inches from the point of attachment.
Service drops, Connections, service head
230.54 (C) Exception - CORRECT ANSWER-24


True/False: One of the means by which grounding conductors and bonding
jumpers shall NOT be connected by is machine screw type fasteners.


Connection of Grounding and Bonding Equipment 250.8 - CORRECT ANSWER-False


Cables with entirely nonmetallic sheaths are permitted to enter the top of a
surface-mounted enclosure through one or more nonflexible raceways not less
than 450 mm (18 in.) and not more than __ feet in length


Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - CORRECT
ANSWER-10


The maximum allowable overcurrent protection for four 14/2 NM cables installed
in contact with thermal insulation without maintaining spacing between cables is:

, Nonmetallic-sheathed cable, Insulation, Ampacity,
334.112, 334.80 - CORRECT ANSWER-15


What kind of protection is required for an outdoor receptacle located under the
soffit of a dwelling for holiday lighting?


Ground-fault circuit interrupters, Outdoors, dwelling units,
210.8(A)(3) - CORRECT ANSWER-GFCI


The minimum rating for a service disconnecting means for a building, other than a
single family dwelling, consisting of three 2 wire circuits shall be__ amperes.


Service equipment, Rating,
230.79(D) - CORRECT ANSWER-60


Where ungrounded conductors are increased in size, equipment grounding
conductors shall be increased in size ___.


Grounding conductors, 250-III, Sizes, 250.122 250.122(B) - CORRECT ANSWER-
proportionately


True/ False: Unless listed for the control of other loads, general use dimmer
switches, shall only be used to control permanently installed incandescent
luminaires.

Información del documento

Subido en
16 de agosto de 2026
Número de páginas
19
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
226
Última venta
-



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes