Prepare for your NFPA 99 MedGas for 6010 Installer Exam with this comprehensive study guide featuring exam questions and verified answers designed to strengthen your knowledge of medical gas and vacuum system installation, testing, safety, and code requirements. This detailed review covers essential topics including NFPA 99 medical gas requirements, Category 1 systems, medical gas and vacuum piping, source equipment, outlets and inlets, zone valve assemblies, master and area alarms, pipe sizing, pressure requirements, brazing procedures, joints and connections, installation practices, pipe identification and labeling, pressure testing, cross-connection prevention, system verification, inspection, documentation, maintenance, and installer safety responsibilities. Ideal for 6010 medical gas installer certification candidates, medical gas technicians, plumbing professionals, contractors, inspectors, engineers, and healthcare facility personnel, this resource is perfect for preparing for certification exams, practice tests, quizzes, and comprehensive MedGas installer assessments while improving knowledge retention, strengthening technical skills, and maximizing exam readiness.

Vista previa del contenido

99 MEDGAS FOR 6010 INSTALLER EXAM (20NFPA 99 MEDGAS FOR 6010 INSTALLER EXAM
Which of the following is NOT permitted to have the medical air compressors
system supply source located outside?
A. vacuum pumps
B. manifolds for gas cylinders
C. instrument air compressors
D. medical air compressors


The ppm gaseous hydrocarbons in the medical air system 25 ppm
shall be less than?



At any level of demand, the medical air dryers shall 32 degrees F
provide air with a dew point below this temperature?



Regulators, filters, and dryers shall be sized to meet the duplexed
peak calculated demand. The piping format for these items
shall be at a minimum?


They can allow an existing system, which is not in Authority Having Jurisdiction (AHJ)
compliance with the NFPA 99 Code to remain in service.



Medical air supply systems operating at different pressures pressure regulator
shall be provided with?



The removal of the outlet connection on a cryogenic liquid unusable
container will cause the container to become?



A building, space, room, or group of rooms intended to laboratory
serve activities involving procedures for investigation,
diagnosis, or treatment in which flammable, combustible,
or oxidizing materials are to be used.


Carbon dioxide and nitrous oxide cylinders shall be kept 20 degrees F
from reaching temperatures below _____.



The master alarm shall activate when the instrument air -22 degrees F
compressor dew point temperature exceeds _____.



In this space, alarm sensors shall be installed on the Category 1
patient's side of each individual zone valve box.



The locations within 6' of the patient's bed and 7'-6" from patient care vicinity
the ceiling, where examinations take place?



Where liquid ring compressors for medical air are used, high water level
the air receiver shall have a local alarm which will shut
down the system due to?


An area where failure of a system is not likely to cause any Category 4 Space
physical impact on a patient.

,99 MEDGAS FOR 6010 INSTALLER EXAM (20NFPA 99 MEDGAS FOR 6010 INSTALLER EXAM
Building or structure, used to house hyperbaric chambers hyperbaric facility
for medical applications and procedures at pressures
above normal atmospheric pressure.


The warning system that provides a continuous visible and area alarm
audible vigilant watch on Category 1 & Category 2 piping
systems.


Moisture concentration of the outlet testing during the 500
verifier purity test shall not exceed how many ppm?



This alarm shall be triggered once the backup instrument local alarm
air compressor is energized.



The components which make up surface mounted medical 1000 degrees F
gas rails shall have a melting point of no less than _____.



When the carbon monoxide level in a medical air system 10
exceeds this ppm level, the local alarm is triggered.



The most remote outlet & the source gas undergo the 5 ppm
verifiers piping purity test. The ppm non-methane variation
between the two shall not exceed?


Building used on a 24-hour basis for medical, psychiatric, hospital
or surgical care of 4 or more patients.



The master alarm shall activate when the medical air dew 35 degrees F
point goes above this temperature.



The location where a person would undergo medical care patient care space
or treatment in a health care facility.



Building or structure used to house hypobaric chambers hypobaric facility
for medical applications and procedures at pressures
below atmospheric pressure.


Copper joints that have been cleaned for brazing shall be 8 hours
used within this time frame?



The activities, systems, or equipment whose failure is not Category 3
likely to cause injury to patients, staff, or visitors, but can
cause discomfort is _____.


The default supply of the central supply piping system is reserve supply
the _____.



The activities, systems, or equipment whose faliure is likely Category 1
to cause major injury or death to patients, staff, or visitors.

,99 MEDGAS FOR 6010 INSTALLER EXAM (20NFPA 99 MEDGAS FOR 6010 INSTALLER EXAM
Maximum oxygen percentage in a medical air 23.5%
proportioning system shall be no higher than?



Orbital welded test coupons shall be inspected at the start 4 hours
of work and at a minimum of how many hours thereafter?



The master alarm will activate when the medical gas line 20%
normal pressure increases/decreases by this percentage.



The section of the central supply system that acts as a supply source
self-contained supply.



The number of cylinders in an instrument air standby 1 hour
header shall be adequate for this amount of time?



Carbon dioxide cylinders shall be prevented from reaching 20 degrees F
temperatures below _____.



The nitrous oxide cylinders shall be prevented from 125 degrees F
reaching temperatures of more than _____.



The quality of instrument air shall be filtered to this micron 0.01
level.



This is the approximate percentage of the Earth's 21%
atmosphere that is oxygen.



The part of the central supply system that will supply the secondary supply
system when the primary has been depleted.



Central supply systems for positive pressure gases shall 50%
have one or more relief valves with this relief setting above
normal operating pressure.


Activities, systems, or equipment whose failure is likely to Category 2
cause minor injury to patients, staff, or visitors.



Alternative air for medical air compressor intakes must 24 hours
have at hand 7days/week and how many hours per day?



Combustible liquids in medical gas systems are those 100 degrees F
which have a flash point at or above this temperature?



The pressure of the Earth's atmosphere, 14.7 is _____. atmosphere absolute

Información del documento

Subido en
16 de agosto de 2026
Número de páginas
23
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$9.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
estudegrades
5.0
(12)
Vendido
27
Seguidores
1
Artículos
1187
Última venta
6 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes