Flammable items should not be located closer than ___ ___ inches from the water heater.
✔Correct Answer-18

Single wall vents require at least _____ _____ of clearance from any combustible material.
✔Correct Answer-6 inches

Double wall vents (or "B" vents) require at least ____ ____ of clearance from any combustible
material. ✔Correct Answer-1 inch

A properly connected water heater will have a flexible gas appliance connector, no more than
____ ____ in length, connecting the water heater to the gas pipe. ✔Correct Answer-6 feet

For proper ventilation for crawl spaces, the IRC requires ___ foot of screen vent for every ___
sqft of space. ✔Correct Answer-1, 150

Crawl space opening minimum: ___ inches x ___ inches. ✔Correct Answer-18, 24

Attic should have an opening of __ inches by __ inches or headroom of less than __ inches.
✔Correct Answer-22, 30, 30

IRC requires safety glass (or safety glazing) for windows that meet all the following
requirements:
- They are more than __ sqft.
- The bottom of the glass is __ inches or less from the floor, and the top of the glass is greater
than __ inches above the floor.
- There is a __-inch walkway on either side of the glass. ✔Correct Answer-9, 18, 36, 36

A chimney must extend at least ___ ___ higher than any portion of a building within ___ feet,
and at least ___ ___ above where it passes through the roof. (3) ✔Correct Answer-2 feet, 10,
3 feet

Decks that are ___ ____ or higher above ground must have a guardrail on all open sides that is
at least ___ ____ high. ✔Correct Answer-30 inches, 36 inches

The space between baluster, spindles, and rails must be less than ___ inches. ✔Correct
Answer-4

, Treads should be at least _____ inches deep. ✔Correct Answer-10

Outdoor hot tubs listed as "self contained for above ground use" and that are at least ___ ___
above the ground are not required to be bonded to a grid. ✔Correct Answer-28 inches

Well head should stick above the ground, usually at least __ inches. ✔Correct Answer-12

The space above the cooktop, required by IRC is a vertical clearance of __ inches between a
cooktop and combustible materials (including cabinets. ✔Correct Answer-30

With the oven, a temperature difference of more than __ degrees over 350, should be reported
as a deficient. ✔Correct Answer-25

Gas connectors must be less than ______ feet in length. ✔Correct Answer-6

A properly installed gas shutoff valve will be connected to the appliance's supply line within
_____ feet of the appliance. ✔Correct Answer-6

A transition duct for a clothes dryer must be visible and no longer than ___ feet. ✔Correct
Answer-8

The clothes dryer exhaust duct may be made of metal, with No. ___ gauge thickness, a diameter
or ___ inches, and a smooth interior finish. And supported at least every ___ feet. ✔Correct
Answer-28, 4, 12

The length of the clothes dryer duct to the termination point should be less than ___ feet.
✔Correct Answer-35

Thick plywood, OSB, or particle board sheets for subflooring can be ____ - ____ thick.
✔Correct Answer-5/8' - 3/4'

Doors should hang in their frames with a clearance of __/___" on the top and sides with __/__"
at the bottom. ✔Correct Answer-1/8", 3/4"

Copper tubing must be supported horizontally every __ feet, Copper piping every __ feet, and
steel piping every __ feet. ✔Correct Answer-6, 12, 12

The main vent stack must extend __ inches or more above the roof. ✔Correct Answer-6

The roof vent must be __ inches away from any wall or vertical surface and __ feet from any
window, to avoid sewer gases expelled through vent. ✔Correct Answer-12, 10

The TPR valve is set to discharge if temperature exceeds ___ degrees or pressure exceeds ___
psi. ✔Correct Answer-210, 150

Información del documento

Subido en
9 de agosto de 2026
Número de páginas
5
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Stuvia2026
2.3
(3)
Vendido
26
Seguidores
1
Artículos
6417
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes