Service entrance conductors run from the service drop to the service box or service panel. True
of false? ✔Correct Answer-- True

The service size is determined by the amperage and the voltage ratings of the service.
✔Correct Answer-- True

Is the service drop overhead or underground? ✔Correct Answer-- Overhead

Are service laterals overhead or underground? ✔Correct Answer-- Underground

The drip loop is typically part of the service drop. True or False? ✔Correct Answer-- False

The wire size for the service drop must be the same as the wire size for the service entrance
conductors. True or False? ✔Correct Answer-- False

How many wires would you typically find in a 240-volt service drop? ✔Correct Answer-- 3

What would 4 wires mean? ✔Correct Answer-- 3-phase electricity

What would 2 wires usually mean? ✔Correct Answer-- 120 volt service

List 7 common problems with service drops. ✔Correct Answer-1. Overhead wires too low.
2. Damaged or frayed wires.
3. Trees or vines interfering with wires.
4. Wires too close to doors or windows.
5. Wires not well-secured to the house.
6. Poor connection between service drop and service entrance.
7. Inadequate clearance from roofs.

List clearances above ground, swimming pools, and roofs. ✔Correct Answer-Clearances
above:
- Roadway 18 ft
- Driveway 12 ft.
- Walkway 10 ft.
- Flat roof 10 ft.
- Sloped roof (e.g., > 4:12) 18 in.
- Low slope roof (e.g., < 4:12) 3 ft.

, - Swimming pool 22.5 ft

The service entrance conductors run from the _________ to the ___________. ✔Correct
Answer-- Service drop to service box

All service entrance conductors must be in conduit. True or False? ✔Correct Answer-- False

All service entrance conductors must be attached above roof level. True or False? ✔Correct
Answer-- False

The drip loop should be as close to the roof as possible. True or False? ✔Correct Answer--
False

List 10 common problems with service entrance conductors. ✔Correct Answer-1. No drip loop
2. No mast head
3. Mast head not weather tight.
4. Mast or conduit bent.
5. Mast or conduit rusted.
6. Mast rotted (if wood).
7. Mast conduit or cable not well secured.
8. Mast conduit or cable not weather tight.
9. Conduit or cable not well sealed at house/wall penetration.
10. Cable frayed, damaged, or covered by siding.

List 4 common areas of water penetration into service entrances. ✔Correct Answer-1. conduit
joints
2. mast head
3. roof flashing
4. meter base
5. house entry

List 2 functions of the drip loop. ✔Correct Answer-1. Prevents water entry into the conduit or
service entrance conductors.
2. Shows that the service drop wires are not straining the splices.

Roughly 999 out of 1000 houses have _________ volts available. ✔Correct Answer-- 240 volts

Roughly 999 out of 1000 houses have __________ service entrance wires. ✔Correct Answer--
3 service entrance wires

Load calculations are part of a home inspection. ✔Correct Answer-- False

Implications of an undersized service include:
a. shock hazard

Información del documento

Subido en
9 de agosto de 2026
Número de páginas
10
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$18.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Stuvia2026
2.3
(3)
Vendido
26
Seguidores
1
Artículos
6417
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes