The energized slot is bigger. True or false? ✔Correct Answer-False, the energized slot is
smaller.

A ____________ receptacle is the most common 120 volt receptacle. ✔Correct Answer--
Duplex receptacle

A duplex receptacle accommodates _____ plugs. ✔Correct Answer-- 2

Based on industry standards, a receptacles is _______ in. from the floor. ✔Correct Answer--
12 in.

Based on industry standards, a receptacles is _______ in. from the floor when serving as a
countertop receptacle. ✔Correct Answer-- 45 in.

Conductors should be secured _____ in. from the box? ✔Correct Answer-- 18 in.

EGC stands for __________ ___________ ____________. ✔Correct Answer-- Equipment
grounding conductor

Receptacles & switches should be connected to the _______? ✔Correct Answer--EGC

Three slot receptacles may not be _____________? ✔Correct Answer-- Ungrounded

Describe the 2 solutions for an ungrounded receptacle. ✔Correct Answer-1) Install GFCI and
label it "no equipment ground"
2) Install EGC to nearest EGC on another branch circuit or o panelboard

A dishonest practice in which a wire is installed between the receptacles EGC terminal (i.e.,
ground, bare conductor) and the ungrounded neutral terminal (i.e., neutral, white conductor) is
called a _________ __________. ✔Correct Answer--bootleg (bad) ground

A bootleg ground does not negatively impact the electrical system. True or false? ✔Correct
Answer-False, a bootleg ground can energize the grounding system.

In order to evenly distribute the load among a branch circuits, a permanently installed appliance
should not exceed ______ % of a general lighting branch circuits amperage rating. ✔Correct
Answer-- 50%

, In order to evenly distribute the load among a branch circuits, a plug installed appliance should
not exceed ______ % of a general lighting branch circuit amperage rating. ✔Correct Answer--
80%

Following the "no point more than 6 ft." rule, the receptacle spacing works out to about every
_______ ft. ✔Correct Answer-- 12 ft.

The max height for a required wall receptacle is 66 in. True or false? ✔Correct Answer-- 66 in.

Measuring horizontally, no point along a countertop wall should be more than _____ in. from a
receptacle. ✔Correct Answer-- 24 in.

Receptacles are always required behind sinks and cooking appliances. True or false? ✔Correct
Answer-False, unless there is more than a 12 in. ledge behind the appliance.

If a receptacle is located above a countertop in an appliance garage (e.g., open ✔Correct
Answer-- Should not be located more than 20 inches above the countertop

If a island is longer than 2 ft. & wider than 1 ft., it requires ______ GFCI receptacles?
✔Correct Answer-- 1 GFCI

Receptacles mounted on a island or peninsula should not be more than _____ in. below the
countertop. ✔Correct Answer-- 12 in.

1 GFCI should be located within 4 ft. of the edge of the bathroom sink. True or false?
✔Correct Answer-False, 1 GFCI receptacle should be located within 3 ft of the edge of the
bathroom sink
-may be mounted on the cabinet if it is no more than 12 inches below the countertop
-none above bathtubs or showers, or flush mounted on countertops

Receptacles can be installed side of a vanity if within ____ in. from the countertop? ✔Correct
Answer-- 12 in.

List the 2 locations receptacles can not be installed in a bathroom. ✔Correct Answer-1) Above
bathtubs & showers (i.e., within the tub/shower surround)
2) Flush mounted on countertop

___________ GFCI receptacles are required in the laundry room. ✔Correct Answer-- At least 1

A receptacle is required if a hall exceeds _____ ft. in length. ✔Correct Answer-- 10 ft.

A receptacle is required in a foyer if the sq. ft. exceeds ____ ft. ✔Correct Answer-- 60 ft.

Información del documento

Subido en
8 de agosto de 2026
Número de páginas
5
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Stuvia2026
2.3
(3)
Vendido
26
Seguidores
1
Artículos
6417
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes