Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 167 páginas
Examen

Sterile Processing Exam : The Essential Question Bank for A+ Success

Document preview thumbnail
Vista previa 4 fuera de 167 páginas

Essential for aspiring and practicing sterile processing and surgical technology professionals! This comprehensive question bank is your ticket to passing the STR exam on your first try. Dive into 300+ exam-level questions covering crucial topics like sterilization methods, biological and chemical indicators, instrument decontamination, and regulatory standards. Each question is paired with a clear, detailed explanation to ensure you not only pass the test but also understand the principles behind it

Vista previa del contenido

1|Page




STERILE PROCESSING / SURGICAL TECHNOLOGY
(STR) Exam 2026-2027 BANK QUESTIONS WITH
DETAILED VERIFIED ANSWERS EXAM QUESTIONS
WILL COME FROM HERE (100% Latest Already Graded
A+




1. The process that destroys all microorganisms including spores is
termed:
A. Sanitization
B. Disinfection
C. Sterilization
D. Antisepsis


Answer: C. Sterilization
Explanation: Sterilization is the complete elimination or destruction of
all forms of microbial life, including bacterial spores. Sanitization
reduces microbial count to safe levels, disinfection eliminates vegetative
pathogens but not necessarily spores, and antisepsis refers to the
application of antimicrobial agents to living tissue.


2. The recommended temperature for steam sterilization under
pressure is:

,2|Page


A. 121°C (250°F)
B. 132°C (270°F)
C. 145°C (293°F)
D. 160°C (320°F)


Answer: B. 132°C (270°F)
Explanation: While 121°C at 15 psi is traditional for gravity
displacement sterilizers, the recommended standard temperature for
steam sterilization is 132°C to 135°C (270°F to 275°F) for dynamic air
removal sterilizers. The higher temperature ensures more efficient
sterilization with shorter exposure times.


3. Which of the following is NOT a recommended method for biological
monitoring of sterilizers?
A. Geobacillus stearothermophilus for steam
B. Bacillus atrophaeus for ethylene oxide
C. Escherichia coli for dry heat
D. Geobacillus stearothermophilus for hydrogen peroxide gas plasma


Answer: C. Escherichia coli for dry heat
Explanation: E. coli is not used as a biological indicator for any
sterilization process. For dry heat sterilization, Bacillus atrophaeus
(formerly Bacillus subtilis) is the appropriate biological indicator
organism. Geobacillus stearothermophilus is used for steam, hydrogen
peroxide gas plasma, and liquid chemical sterilization processes.

,3|Page




4. The Bowie-Dick test is performed to:
A. Test biological lethality
B. Assess steam penetration in dynamic air removal sterilizers
C. Evaluate chemical indicator performance
D. Measure sterilizer chamber temperature


Answer: B. Assess steam penetration in dynamic air removal sterilizers
Explanation: The Bowie-Dick test is a diagnostic test performed daily on
dynamic-air-removal (prevacuum) steam sterilizers to evaluate air
removal and steam penetration. It is not a biological test and does not
verify sterilization; rather, it detects air leaks and inadequate air
removal that could compromise sterilization.


5. Which solution is considered a high-level disinfectant when used at
appropriate concentrations and contact times?
A. 70% isopropyl alcohol
B. 2% glutaraldehyde
C. 10% povidone-iodine
D. 3% hydrogen peroxide


Answer: B. 2% glutaraldehyde
Explanation: Glutaraldehyde at 2% concentration is classified as a high-
level disinfectant capable of killing all microorganisms except large

, 4|Page


numbers of bacterial spores when used with proper contact time. It is
commonly used for heat-sensitive semi-critical devices. Isopropyl alcohol
is an intermediate-level disinfectant, povidone-iodine is an antiseptic,
and hydrogen peroxide has varying efficacy depending on
concentration.


6. The primary purpose of using a biological indicator in a sterilization
process is to:
A. Monitor temperature fluctuations
B. Confirm the presence of viable organisms after the cycle
C. Provide direct evidence of sterility
D. Test the mechanical function of the sterilizer


Answer: B. Confirm the presence of viable organisms after the cycle
Explanation: Biological indicators provide direct evidence that the
sterilization process has killed the most resistant organisms. A negative
result after incubation indicates that the spores have been killed,
demonstrating that the sterilizer delivered a lethal challenge. Biological
monitoring is considered the highest standard for verifying sterilization
efficacy.


7. In the sterile processing department, the term "IFU" refers to:
A. Integrated Function Unit
B. Instructions for Use
C. Instrument Fixation Unit

Información del documento

Subido en
5 de agosto de 2026
Número de páginas
167
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$25.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
2
Seguidores
2
Artículos
1446
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes