Build Your Career in Structural Steel! This massive 300+ question bank covers EVERY aspect of the New Mexico GS-24 certification—from OSHA Subpart R compliance and AISC standards to crane operation and welding inspection. Master column splices, bolt connections, safety protocols, and load calculations with detailed rationales explaining real-world applications. Essential for steel erectors, construction supervisors, engineers, and safety professionals. Your blueprint for certification success

Vista previa del contenido

1|Page




NEW MEXICO GS-24 STRUCTURAL STEEL ERECTION
Exam 2026-2027 BANK QUESTIONS WITH DETAILED
VERIFIED ANSWERS EXAM QUESTIONS WILL
COME FROM HERE (100% Latest Already Graded A+




QUESTION 1
In structural steel erection, the term "column splice" refers to which of
the following?
A) A connection that joins two beam ends in a straight line
B) A vertical joint that connects two column sections end-to-end
C) A horizontal connection between a beam and a girder
D) A temporary bolted connection used during hoisting


ANSWER: B
Explanation: A column splice is specifically a vertical end-to-end
connection of two column sections to achieve the required building
height. This connection is typically located a few feet above the floor or
erection level to allow for practical assembly and to avoid the most
highly stressed regions of the column. Column splices are distinct from
beam splices and are designed to transfer axial loads, shear, and
moment, depending on the connection detailing.

,2|Page




QUESTION 2
The New Mexico State Construction Industries Division adopts which
national standard as the primary regulatory reference for structural
steel erection?
A) ASTM A36
B) AISC 303-10
C) OSHA 29 CFR Part 1926, Subpart R
D) AWS D1.1


ANSWER: C
Explanation: OSHA 29 CFR Part 1926, Subpart R—Steel Erection—is the
primary federal standard adopted by New Mexico for structural steel
erection. While AISC and AWS standards are industry best practices and
often referenced, Subpart R contains the specific mandatory safety and
operational requirements that govern steel erection activities in New
Mexico. Subpart R addresses fall protection, structural stability, column
anchorage, and hoisting operations.




QUESTION 3
According to OSHA Subpart R, what is the maximum allowable gap
between the edge of a walking/working surface and the edge of a
structural member for a 30-inch-wide decking panel?

,3|Page


A) 2 inches
B) 6 inches
C) 12 inches
D) 18 inches


ANSWER: B
Explanation: The maximum gap permitted is 6 inches when using 30-
inch-wide metal decking panels. This is established to prevent workers'
feet or legs from falling through the opening. The gap is measured from
the edge of the walking surface to the supporting structural member.
Wider gaps increase the risk of falls and require additional fall
protection measures.




QUESTION 4
When using a wire rope sling during steel erection, what minimum
safety factor is required by OSHA for the sling's rated capacity?
A) 3:1
B) 5:1
C) 7:1
D) 10:1


ANSWER: B

, 4|Page


Explanation: OSHA requires a minimum design factor of 5:1 for wire
rope slings used in construction, meaning the breaking strength must be
at least five times the maximum intended load. This safety factor
accounts for dynamic loading, wear, and variations in rope
construction. While a 10:1 factor is used for personnel hoisting, the
standard for material handling is 5:1.




QUESTION 5
In an AISC steel connection, a "shear connection" is primarily designed
to transmit:
A) Bending moment only
B) Axial tension only
C) Vertical and horizontal shear forces with minimal moment
D) Torsional forces only


ANSWER: C
Explanation: A shear connection, such as a double-angle or single-plate
connection, is designed to transfer vertical and horizontal shear forces
between connected members while allowing for rotation. These
connections are assumed to have negligible moment capacity, meaning
the beam end is free to rotate. The AISC Steel Construction Manual
classifies these as "simple" connections.

Información del documento

Subido en
5 de agosto de 2026
Número de páginas
191
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$25.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
2
Seguidores
2
Artículos
1446
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes