Vista previa 2 fuera de 8 páginas
Examen

Pneumatics Test Questions and Answers

Document preview thumbnail
Vista previa 2 fuera de 8 páginas

Pneumatics Test Questions and Answers

Vista previa del contenido

Pneumatics Test Questions and Answers


The first factor contributing to the quality of compressed air that can be produced is
the condition of the blank at the system air intake. - ANS-atmospheric air

Name five materials that may be used to make the element in a dry filter for use in
pneumatic systems. - ANS-a. Paper
b. Plastic
c. Cloth
d. Ceramic
e. metal

Name two things that occur when warm, humid, high pressure air cools in the
distribution lines of a pneumatic system. - ANS-a. The pressure of the compressed
air drops according to the general gas law.
b. If the temperature reduces to the dew point liquid water can form in the
distribution lines.

The blank is the temperature at which water vapor in the air begins to condense to
form liquid water. - ANS-Dew point

Name five places where liquid water may form in the pneumatic system. - ANS-a.
Distribution lines
b. Intercooler
c. Moisture separator
d. Receiver
e. aftercooler

In addition to air storage, the receiver dampens BLANK caused by compressor
operation. - ANS-air pulsations

The BLANK compressed-air-distribution system distributes air from a single location
to all workstations in a facility. - ANS-centralized grid

Which design of air distribution system is generally considered to provide maximum
airflow with a minimum of flow resistance? - ANS-Loop system

List the three key variables that make the application of a simple formula for the
calculation of distribution line sizes impractical. - ANS-a. Consumption varies
considerably during operation
b. The line serves several stations,
c. The different stations all intermittently use actuators.

Identify the two factors that are critical to selecting the actual sizes of the lines

, used in an air distribution system. - ANS-a. The total air consumption of all
actuators
b. Pressure drop caused by the lines and fittings.

What can be used to supply compressed air to a section of the distribution system
that contains equipment using a large volume of air on an intermittent basis
without increasing the size of the system? - ANS-An auxiliary air receiver can be
used to provide extra air pressure for high occasional use components.

Name the two ways in which a two-stage filter traps and removes unwanted
particles. - ANS-a. Centrifugal force
b. Porous materials

Why is it necessary to use a pressure regulator and what can this cause. - ANS-The
pressure regulator promotes consistent operating pressure for the tools and circuits
powered by the station. It also maintains the desired system output pressure.

What is a disadvantage of the direct-operated pressure regulator and what can this
cause. - ANS-It provides pressure control, but directly exposes he diaphragm to
system airflow. This exposure subject the diaphragm to any foreign materials in the
air, which may shorten the life of the component. Direct exposure also effects
regulator accuracy and sensitivity.

The pressure setting of regulators using a flexible diaphragm is set by controlling
the force BLANK applied to the diaphragm. - ANS-(either spring or screw)

What is the advantage of the relieving -type pressure regulator? - ANS-It acts as a
small scale relief valve to prevent pressures higher than the regulator pressure
setting. Prevents over pressure from damaging actuators.

The force produced by the pilot-chamber air pressure replaces the force generated
by the BLANK of the basic regulator design. - ANS-diaphragm control spring

In typical pneumatic system lubricators, oil is atomized by adding oil to an
airstream through an BLANK orifice. - ANS-oil-drip

What is the most common rigid conductor for major pneumatic systems? - ANS-
pipe

List four factors that should be considered to minimize installation costs and reduce
pressure losses in applications using hose for the distribution of compressed air. -
ANS-a. Hoses should be no longer than necessary
b. Hoses should be no larger in diameter than necessary
c. A minimum number of fittings and couplings should be used
d. Layout lines to eliminate kinks and reduce the number of bends.

The atmosphere blankets earth with a layer of gases approximately BLANK miles
deep. - ANS-360

Información del documento

Subido en
1 de agosto de 2026
Número de páginas
8
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$12.79

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
CLOUNDLite
3.9
(128)
Vendido
659
Seguidores
389
Artículos
12325
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes