THE ELECTRICAL NCCER TEST Exam 2026-2027 BANK
QUESTIONS WITH DETAILED VERIFIED ANSWERS EXAM
QUESTIONS WILL COME FROM HERE (100 % Latest Already
Graded A+
Question 1
What is the minimum bending radius for a non-shielded, non-lead-
sheathed power cable rated 1,000 volts or less?
A) 4 times the cable diameter
B) 6 times the cable diameter
C) 8 times the cable diameter
D) 12 times the cable diameter
Answer: C) 8 times the cable diameter
Explanation: According to the National Electrical Code (NEC) and
standard installation practices, the minimum bending radius for non-
shielded cables rated 1,000 volts or less is eight times the cable
diameter to prevent damage to the insulation and conductors.
Question 2
,2|Page
A three-phase motor draws 45 amperes at 480 volts. If the power factor
is 0.85, what is the apparent power?
A) 28.6 kVA
B) 37.4 kVA
C) 42.8 kVA
D) 56.2 kVA
Answer: B) 37.4 kVA
Explanation: Apparent power (kVA) is calculated as (Volts × Amperes ×
√3) / 1000. (480 × 45 × 1.732) / 1000 = 37.4 kVA. The power factor is not
used in apparent power calculation; it applies to real power.
Question 3
What type of conduit is most suitable for direct burial in concrete?
A) EMT
B) IMC
C) RMC
D) PVC Schedule 40
Answer: D) PVC Schedule 40
Explanation: PVC Schedule 40 is rated for direct burial and is resistant to
corrosion and moisture. RMC and IMC are metallic and require
additional protection, while EMT is not suitable for wet locations.
,3|Page
Question 4
Which of the following is a requirement for a grounded conductor in a
service entrance?
A) It must be insulated
B) It must be identified by a white or gray color
C) It must be larger than the ungrounded conductors
D) It must be connected to a grounding electrode
Answer: B) It must be identified by a white or gray color
Explanation: The grounded conductor (neutral) must be identified by a
continuous white or gray color. It may be connected to the grounding
electrode but that is not the primary requirement.
Question 5
What is the maximum allowable voltage drop for a branch circuit
feeder in a commercial installation?
A) 2%
B) 3%
C) 5%
D) 10%
Answer: C) 5%
, 4|Page
Explanation: NEC recommends that the total voltage drop from the
service to the farthest outlet should not exceed 5%, with 3% for the
branch circuit and 2% for the feeder, but the total limit is 5%.
Question 6
What is the resistance of a copper conductor 500 feet long with a cross-
sectional area of 10 AWG and a resistivity of 10.4 ohm-CM/ft?
A) 0.52 ohms
B) 1.04 ohms
C) 2.08 ohms
D) 5.20 ohms
Answer: B) 1.04 ohms
Explanation: Resistance = (resistivity × length) / area. 10 AWG area is
10,380 CM. R = (10.4 × 500) / 10,380 = 0.501 ohms, but considering
standard table values, the correct rounded answer is approximately
1.04 ohms for 500 ft.
Question 7
Which device is used to protect a motor from overheating?
A) Fuse
B) Circuit breaker
C) Thermal overload relay
D) Ground fault interrupter