Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 35 páginas
Examen

OHIO STATE FIRE ALARM EXAM 2026/2027 | Actual Exam Questions & Answers | Fire Alarm Systems Certification | Pass Guaranteed - A+ Graded

Document preview thumbnail
Vista previa 4 fuera de 35 páginas

OHIO STATE FIRE ALARM EXAM 2026/2027 | Actual Exam Questions & Answers | Fire Alarm Systems Certification | Pass Guaranteed - A+ Graded

Vista previa del contenido

OHIO STATE FIRE ALARM EXAM 2026/2027 |
Actual Exam Questions & Answers | Fire
Alarm Systems Certification | Pass
Guaranteed - A+ Graded




Question 1: A two-wire Class B circuit has 10 smoke detectors on it. A Class B
circuit will typically have an end-of-line device on the last detector in the circuit.
The end-of-line device is usually a _____.

A) Capacitor
B) Resistor
C) Diode
D) Transformer

Correct Answer: B
Rationale: A Class B circuit uses an end-of-line resistor to supervise the circuit for
integrity. The resistor allows the panel to detect opens or shorts in the wiring .




Question 2: Smoke detectors installed in air duct systems are normally used to
control spreading smoke.

A) True
B) False

Correct Answer: A
Rationale: Duct smoke detectors are primarily installed to prevent the spread of smoke
through HVAC systems by initiating fan shutdown, damper closure, or other smoke
control functions .

,Question 3: A smoke detector installed in an air duct system is permitted to be
used as a substitute for open area protection.

A) True
B) False

Correct Answer: B
Rationale: Duct detectors cannot substitute for open area protection. Areas in ducts,
below floors, and above ceilings are considered separate areas requiring their own
detection .




Question 4: If control circuits are used to shut down elevator power, the control
circuits are not required to be monitored for the presence of operating voltage.

A) True
B) False

Correct Answer: B
Rationale: Control circuits used for elevator power shutdown must be monitored for
the presence of operating voltage to ensure supervisory integrity .




Question 5: According to the Ohio Fire Code, in a covered mall building exceeding
50,000 ft² in area, a(n) ______ shall be provided.

A) Emergency Voice/Alarm Communications System
B) Manual pull station system
C) Waterflow alarm system
D) Local only alarm system

Correct Answer: A
Rationale: Covered mall buildings exceeding 50,000 square feet require an Emergency
Voice/Alarm Communications System to ensure effective evacuation communication .

,Question 6: A detector that is capable of resetting itself when the heat in the area
drops below the detector's set point is called a:

A) Nonrestorable heat detector
B) Restorable heat detector
C) Rate-of-rise detector
D) Fusible link detector

Correct Answer: B
Rationale: A restorable heat detector automatically resets when the temperature drops
below its set point after activation .




Question 7: Any alarm that occurs that is not the result of a potentially hazardous
condition is known as:

A) False alarm
B) Unwanted alarm
C) Nuisance alarm
D) Supervisory alarm

Correct Answer: B
Rationale: An unwanted alarm is defined as any alarm that occurs that is not the result
of a potentially hazardous condition .




Question 8: Smoke detectors must be functionally tested:

A) Monthly
B) Quarterly
C) Annually
D) Every 5 years

, Correct Answer: C
Rationale: NFPA 72 requires smoke detectors to be functionally tested on an annual
basis .




Question 9: Smoke alarms or smoke detectors are required at what locations?

A) In each sleeping room only
B) Outside each sleeping room only
C) On each level only
D) In each sleeping room, outside each sleeping room, and on each level

Correct Answer: D
Rationale: Smoke alarms are required in every sleeping room, outside each sleeping
area, and on every level of the home including basements .




Question 10: A Class X circuit is a redundant pathway that only applies to
addressable fire alarm signaling device circuits.

A) True
B) False

Correct Answer: A
Rationale: Class X circuits provide a redundant pathway, allowing continued
communication even with a single open or short circuit, and applies specifically to
addressable systems .




Question 11: When installing a smoke detector for door release service and the
depth of the wall above the door is greater than 24 inches on one side only, we
must install _____ ceiling-mounted detector(s) on the higher side or ____ wall-
mounted detector(s) (one on each side of the doorway).

A) 1, 2
B) 2, 1

Información del documento

Subido en
23 de julio de 2026
Número de páginas
35
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$43.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Dock2
4.0
(4)
Vendido
21
Seguidores
11
Artículos
3565
Última venta
2 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes