Where vents, including those for direct-vent appliances or combustion air intake pipes,


penetrate outside walls of buildings, the annular spaces around such penetrations


shall be ___________ using approved materials to prevent entry of combustion products


into the building. - Correct answer Permanently sealed




The air that passes through the combustion chamber in excess of that which is


required for complete combustion is called what? - Correct answer Excess air




__________ shall have a vertical clearance above the cooking top of NOT less than 30


inches to combustible material or metal cabinets. - Correct answer Household cooking


appliances




The pipe or duct which connects a fuel gas burning appliance to vent or chimney is


what? - Correct answer Vent connector

,Piping in systems shall be run as __________ as is practical from one point to another. -


Correct answer Directly




Underground metallic piping shall be protected against ___________ as warranted by


soil conditions. - Correct answer Corrosion




ASME containers installed in enclosed spaces on vehicles shall be constructed for at


least a _______ design pressure. - Correct answer 312 psig




If cylinders used in industrial occupancies for processing, research or experimental


purposes are manifolded together, the total propane capacity shall NOT exceed


_________. - Correct answer 300 lbs




Polyethylene and polyamide piping shall be installed outside and underground with a


minimum of ________ cover. - Correct answer 12 inches




If outside, piping shall be under the vehicle and _______________. - Correct answer

Below any insulation or false bottom

,Re-circulating direct gas-fired industrial air heaters shall NOT ____________ in buildings


that contain flammable solids, gases, explosive materials, or substances that may


become toxic when exposed to flame. - Correct answer Re-circulate room air




NFPA 54/ANSI Z223.1, National Fuel Gas Code, shall be administered and enforced by


_____________ designated by the governing authority. - Correct answer The authority


having jurisdiction




A system being leak tested should show no increase or decrease in the pressure


reading for a period of ______________. - Correct answer 3 minutes




____________ are appliances that are constructed and installed so that all air for

combustion is derived directly from the outside atmosphere and all flue gases are


discharged outdoors. - Correct answer Direct vent appliances




A vent connector shall NOT be connected to a chimney flue serving a fireplace unless

the fireplace flue opening is _____________. - Correct answer Permanently sealed

, Fuel containers shall be ____________ to prevent jarring loose. - Correct answer


Mounted




ASME containers and cylinders on vehicles utilized for other than engine fuel systems,


shall NOT be ____________ inside the vehicle. - Correct answer Stored, installed, or


transported




Containers used in a public building undergoing minor renovations shall NOT have


more than a maximum propane capacity of ______________ and the number of cylinders


shall NOT exceed the number of workers assigned to use the LP gas. - Correct answer


20 lbs




Field welding on containers shall be limited to attachments on ____________ installed by


the manufacturer. - Correct answer Non-pressure parts




During the hours of the day the public is permitted in a building undergoing minor

renovations, the cylinders shall NOT be ____________. - Correct answer Left unattended

Información del documento

Subido en
22 de julio de 2026
Número de páginas
41
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.89

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
10
Seguidores
0
Artículos
837
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes