• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 32 páginas
Examen

Propane Final Practice Questions and Correct Answers 2026

Document preview thumbnail
Vista previa 4 fuera de 32 páginas

This document contains a comprehensive collection of propane final practice questions and correct answers covering LP-gas codes, NFPA 54 and NFPA 58 requirements, propane installations, safety regulations, and system operations. It includes topics such as propane containers, pressure relief devices, gas piping, venting systems, regulators, emergency shutoff valves, pressure testing, ASME containers, DOT cylinders, transportation, appliance installation, and Oklahoma LP-Gas regulations. The material is presented in a question-and-answer format, making it an effective study guide for certification, licensing, exam preparation, and review.

Vista previa del contenido

Propane Final Practice Update
Questions And Correct Answers


Cylinders stored within a residential building, including the basement or any
storage area in a common basement of a multiple-family building and attached
or detached garages, shall be limited to cylinders each with a maximum water
capacity of _______ and shall NOT exceed 5.4 lb aggregate water capacity per
each living space unit.

2.7 lbs




All new Class I permit holders must provide bulk storage capacity of NOT less
than an aggregate of ___________ water gallons.

18,000




LP-gas containers shall be located __________ unless specifically allowed to be
inside.

Outside buildings




Effective January 1, 1993, a ________ shall be applied to all portable refillable
LP-Gas cylinders of 100 lbs or less NOT filled on site.

Warning Label

,A Type B or Type L gas vent shall terminate at least _________ in vertical height
above the highest connected appliance draft hood or flue collar.

5 feet




All appliances using electrical controls shall have the controls connected into a
________.

Permanently live circuit




All LP gases shall be _______ prior to delivery with a warning agent down to a
concentration in air of NOT over 1/5 the lower flammability limit.

Odorized




All metallic equipment and components that are ______ shall be coated or
protected and maintained to minimize corrosion.

Buried or mounded




The upper flammability limit of propane vapor is _____.

9.6

,A sniff test is done to ______ when LP-gas is delivered to the bulk plant.

Detect odorization




A clearly identified and accessible switch or circuit breaker shall be installed at
a location NOT less than _______ or more than 100 feet from the dispensing
device to shut off power in the event of a fire, accident, or other emergency.

20 feet




Where work is being performed on piping that contains gas, provisions for
___________ shall be made before alterations are made in a metallic piping
system.

Electrical continuity




Air for cooling, heating, or ventilation distributed to habitable spaces is known
as __________.

Circulating air

, ASME code refers to the __________ of the American Society of Mechanical
Engineers.

Boiler and pressure vessel code




A chimney for residential type or low heat appliances shall extend at least 2
feet higher than any portion of a building with a horizontal distance of
__________.

10 feet




The location where connections and disconnections are made or where LP-Gas
vented to the atmosphere in the course of transfer operations is known as
__________.

Point of transfer




Appliances or equipment that, because of their intended modes of use or
operation, are capable of providing sufficient thermal energy to ignite
flammable gas-air mixtures are known as _________.

Sources of ignition




Where ___________ are used, they shall NOT extend from room to room or
pass through walls.

Flexible connectors

Información del documento

Subido en
20 de julio de 2026
Número de páginas
32
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Hosmerit
4.7
(261)
Vendido
437
Seguidores
46
Artículos
4713
Última venta
8 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes