RADIATION THERAPY EXAMS SCRIPT

Vista previa del contenido

RADIATION THERAPY EXAMS SCRIPT 2026/2027
QUESTIONS AND SOLUTIONS RATED A+
✔✔Compared to water, the density of bone is:

A. 1.00
B. 1.65-1.85
C. 0.33-0.35
D. 0.2-0.26 - ✔✔B. 1.65-1.85

✔✔If the width of the vertebral body is 5.3 cm and measures 7.5 cm on the portal
verification film, the magnification factor is:

A. 0.706
B. 1.0
C. 1.41
D. 2.00 - ✔✔C. 1.41

7.5/5.3 = 1.41

✔✔A patient's treatment will be 2.54 minutes. How many seconds is this?

A. 174
B. 152.4
C. 114
D. 254.0 - ✔✔B. 152.4

(60/1)(x/2.54)

1x = 60(2.54)

X = 152.4

✔✔How many cobalt sources are contained in the gamma knife unit?

A. 25
B. 105
C. 201
D. 280 - ✔✔C. 201

✔✔Which of the following is a nonmalignant condition treated by stereotactic
radiosurgery?

A. Nasopharyngeal tumors
B. Medulloblastoma

,C. Astrocytoma
D. Arteriovenous malformation - ✔✔D. Arteriovenous malformation

✔✔The distance between the entrance and exit points for parallel opposed fields is
called the:

A. Source to skin distance
B. Source to axis distance
C. Interfield distance
D. Source to tray distance - ✔✔C. Interfield distance

✔✔A lateral portal verification shows the spinal cord to be at a measured depth of 9 cm
from the skin surface. If the film magnification is 1.5, the actual depth of the cord is:

A. 4 cm
B. 6 cm
D. 9 cm
E. Not enough information - ✔✔B. 6 cm

9/1.5 = 6

✔✔In craniospinal irradiation, using 100 cm SSD, the spinal cord field length is 30 cm.
The skull field length is 15 cm. To align the skull field with the divergent spinal field, the
amount of collimator rotation required for the skull field is:

A. 4.3 degrees
B. 10 degrees
C. 5 degrees
D. 8.53 degrees - ✔✔D. 8.53 degrees

* the rotation of the collimator for the skull field is given by applying the divergence
formula:

Tan⁻¹ ((A/2)(SSD))

The divergence of the spine field is what needs to be known so the collimator angle is
parallel.

Therefore,

Tan⁻¹ ((30/2)(100)) = 8.53

✔✔In craniospinal irradiation, using 100 cm SSD, the spinal cord field length is 30 cm.
The skull field length is 15 cm. To eliminate divergence of the the brain portal into the

,spinal portal while treating the lateral brain fields, the couch should be rotated ____
degrees toward the gantry.

A. 8.53 degrees
B. 6.3 degrees
C. 5.3 degrees
D. 4.3 degrees - ✔✔D. 4.3 degrees

✔✔When treating a left lateral field, the gantry is 90 degrees and the collimator angle is
25 degrees. If an opposing right lateral port is planned with a gantry angle of 270
degrees, the collimator angle should be:

A. 25 degrees
B. 335 degrees
C. 245 degrees
D. 0 degrees - ✔✔B. 335 degrees

90 - 25 = 65

270 + 65 = 335

✔✔If a 1.0 cm Bolus is applied to an area being treated with a 6 MV beam. The
maximum dose point will be located at:

A. The skin surface
B. 0.5 cm below the skin surface
C. 1.0 cm below the skin surface
D. 1.5 cm below the skin surface - ✔✔B. 0.5 cm below the skin surface

*dose maximum is located at 1.5 cm below the skin for a 6 MV beam. If a 1.0 cm Bolus
is then used, the dose maximum is raised to 0.5 cm below the skin surface.

✔✔A patient is mistakenly treated at 82 cm SSD instead of 8o cm SSD due to a
misalignment of the ODI. The planned dose was 300 cGy. What was the approximate
dose delivered?

A. 285 cGy
B. 292 cGy
C. 308 cGy
D. 315 cGy - ✔✔A. 285 cGy

300/x = 82^/80^2

82^2 = 6724

, 80^2 = 6400

300 x 6400 = 1,920,000

X = 1,920,000/6724

X = 285.54

✔✔A 360 degree rotation has an MU/degree of 0.72 MU/degree. How many monitor
units will be delivered?

A. 180
B. 200
C. 259
D. 360 - ✔✔C. 259

360 x 0.72 = 259

✔✔An air filled balloon positioned with a catheter in the bladder is an example of _____
contrast.

A. Soluble
B. Insoluble
C. Negative
D. Positive - ✔✔C. Negative

✔✔Contrast media may be administered:

1. IV
2. Oral
3. Catheter

A. 1 & 2
B. 1 & 3
C. 2 & 3
D. All of the above - ✔✔D. All of the above

✔✔In CT simulation, therapists may alter kVp to lower dose.

A. True
B. False - ✔✔B. False

✔✔The identification of treatment fields relative to stable landmarks is:

A. Localization

Información del documento

Subido en
20 de julio de 2026
Número de páginas
39
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TUTORJOEL
3.6
(45)
Vendido
300
Seguidores
11
Artículos
37055
Última venta
4 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes