MED GAS NFPA WORKSHEET -3.

Vista previa del contenido

MED GAS NFPA WORKSHEET #3

Inlet filtration of the medical-surgical vacuum central supply systems shall contain all
except which of the following essentials? - answer filtration shall be sized a minimum of
50% of peak demand

vacuum piping for _____ shall be connected separately from the medical surgical
system directly to the receiver tank through its own isolation valve and fluid trap located
at the receiver - answer a teaching laboratory

which of these is an acceptable location for the exhaust of medical vacuum? -
answeraway from public places

where WAGD is produced by the medical surgical vacuum source, the total
concentration of oxidizers shall be maintained below _____ percent - answer23.6 %

which source shall NOT be used to power the venturi for the WAGD system -
answermedical air

oxygen central supply systems with an oxygen concentrator, having three supply
sources, shall NOT be allowed if: - answera documented risk analysis has NOT been
completed

except for zone and future valves, all valves shall be located in secured areas such as
locked pipe chases or be: - answerlocked or latched in their operating posititon

with the approval of the authority having jurisdiction, in which areas shall the shutoff
valves be permitted to be secured to prevent inappropriate access? - answerpediatric

what is the minimum flow coefficient (Cv) different allowed between inlet side and outlet
side of a full open 1-inch positive pressure valve? - answer60

where multiple freestanding buildings are being served by one central supply source,
what minimum number of main line shutoff valves is required? - answerone for each
building

riser valves are located where? - answerin the riser adjacent to the main line

which of the following is a requirement for the configuration of a zone valve box? -
answerplaced such that a wall intervenes between the inlets/outlets they control

zone valves are NOT permitted to be installed in which of these locations? - answerin
the same room as the outlets/inlets that it serves

Información del documento

Subido en
17 de julio de 2026
Número de páginas
3
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$16.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Resolution
4.0
(61)
Vendido
313
Seguidores
188
Artículos
16070
Última venta
1 semana hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes