Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 23 páginas
Examen

ACI Concrete Field Testing Technician- Grade I Exam Questions With Correct Answers

Document preview thumbnail
Vista previa 3 fuera de 23 páginas

ACI Concrete Field Testing Technician- Grade I Exam Questions With Correct Answers

Vista previa del contenido

ACI Concrete Field Testing Technician- Grade I
Exam Questions With Correct Answers


The sensor of the temperature measuring device shall be submerged a
| | | | | | | | | | |



minimum of _____ in. [_____mm] into the freshly mixed concrete. -
| | | | | | | | | | |



CORRECT ANSWER✔✔-3 in. [75 mm]
| | | |




The temperature measuring device shall have a capacity of measuring
| | | | | | | | | |



temperature of freshly mixed concrete to +- _____ degrees F [+- _____
| | | | | | | | | | | |



C] throughout a range of _____. - CORRECT ANSWER✔✔-1 degree F [0.5
| | | | | | | | | | |



C], 30 degrees F to 120 F [0 C to 50 C]
| | | | | | | | | | | |




The temperature measuring device shall be calibrated _____, or
| | | | | | | | |



whenever there is a question of _____. - CORRECT ANSWER✔✔-
| | | | | | | | |



Annually, accuracy |




The temperature of concrete may be measured in a wheelbarrow. True
| | | | | | | | | | |



or False? - CORRECT ANSWER✔✔-True
| | | |




The temperature of concrete may be measured in a wall form. True of
| | | | | | | | | | | | |



False - CORRECT ANSWER✔✔-True
| | |

,A composite sample of concrete is required even if the only purpose for
| | | | | | | | | | | | |



obtaining the sample is to determine temperature. True of False? -
| | | | | | | | | | |



CORRECT ANSWER✔✔-False |




What must be done to the sample container prior to sampling the
| | | | | | | | | | | |



concrete? - CORRECT ANSWER✔✔-Dampen (with water)
| | | | |




What must be done to the concrete surrounding the temperature
| | | | | | | | | |



measuring device after the device is submerged in the fresh concrete. -
| | | | | | | | | | | |



CORRECT ANSWER✔✔-Gently press the concrete around the
| | | | | | |



temperature measuring device at the surface of the concrete
| | | | | | | |




How long must the temperature measuring device remain in the freshly
| | | | | | | | | | |



mixed concrete? - CORRECT ANSWER✔✔-At least 2 minutes but not
| | | | | | | | | |



more than 5 minutes
| | |




After the temperature of the concrete is read, what is required? -
| | | | | | | | | | | |



CORRECT ANSWER✔✔-Reporting of temperature
| | |




The temperature of concrete is reported to the nearest _____ degrees F
| | | | | | | | | | | |



[_____ C] - CORRECT ANSWER✔✔-1 degree F [0.5 C]
| | | | | | | |

, According to ASTM C1064, what is one reason to take the temperature
| | | | | | | | | | | |



of concrete? - CORRECT ANSWER✔✔-Verify conformance to a specified
| | | | | | | | |



requirement for temperature of concrete | | | |




A maximum temperature of freshly mixed concrete is specified in ASTM
| | | | | | | | | | |



C1064. True of False? - CORRECT ANSWER✔✔-False
| | | | | |




The sample of concrete used for temperature determination must be
| | | | | | | | | |



rodded 25 times. True or False? - CORRECT ANSWER✔✔-False
| | | | | | | |




Sampling by this method is required when tests are to be made to
| | | | | | | | | | | | |



determine _____ with specification requirements. - CORRECT
| | | | | | |



ANSWER✔✔-Compliance


This method covers sampling from four types of mixtures which are
| | | | | | | | | | |



_____, _____, _____, and _____. - CORRECT ANSWER✔✔-Stationary
| | | | | | | |



mixers, paving mixers, revolving drum mixers, and open top mixers
| | | | | | | | |




The maximum allowable time between obtaining the first and final
| | | | | | | | | |



portions of a composite sample is _____ minutes. - CORRECT
| | | | | | | | | |



ANSWER✔✔-15

Información del documento

Subido en
26 de junio de 2026
Número de páginas
23
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectphilip
4.0
(42)
Vendido
288
Seguidores
7
Artículos
26613
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes