• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 39 páginas
Examen

FDNY COF P-98 Exam & Practice Test 2026/2027 – Complete Exam-Style Questions with Detailed Rationales | 100% Verified – Pass Guaranteed – A+ Graded

Document preview thumbnail
Vista previa 4 fuera de 39 páginas

FDNY COF P-98 Exam 2026/2027 – Real-Style Exam Questions | 100% Correct Answers | Torch Operations | Fire Safety | Cutting & Welding | Hot Work Permits | FDNY Regulations | Detailed Rationales | Graded A+ Verified – Pass Guaranteed – Instant Download

Vista previa del contenido

FDNY COF P-98 Exam & Practice Test 2026/2027 – Complete
Exam-Style Questions with Detailed Rationales | 100% Verified –
Pass Guaranteed – A+ Graded


Instructions: Read each question carefully. Select the one best answer. Each question
has only one correct answer.




QUESTION 1

Acetylene gas is stored as a liquid in containers under pressure. What is the maximum
safe working pressure for acetylene when used in welding and cutting operations?

A. 5 psi

B. 10 psi

C. 15 psi

D. 25 psi

Correct Answer: C

Rationale: Per FDNY Fire Code FC 2605.4 and the G-60 study material, acetylene gas
shall not be utilized at a pressure exceeding 15 pounds per square inch gauge (psig).
Setting the regulator above 15 psi can cause the acetylene to decompose explosively.
Acetylene is dissolved in a suitable solvent within the container for safe storage and
use.

,QUESTION 2

True or False: Copper tubing may be used to splice an acetylene hose if the connection
is properly secured.

A. True

B. False

Correct Answer: B

Rationale: FALSE. Per the G-60 study material and FC 2605.4, copper tubing should
never be used to splice acetylene hose. Copper reacts chemically with acetylene, and
the reaction may cause an explosion if the tube is subjected to a physical blow. Only
approved hose connections and fittings designed for acetylene service may be used.




QUESTION 3

A contractor is performing oxy-acetylene cutting on a construction site. According to
FDNY Fire Code Chapter 26, what is the minimum separation distance required between
the cutting operation and combustible materials?

A. 15 feet

B. 25 feet

C. 35 feet

D. 50 feet

Correct Answer: C

,Rationale: Per FC 2604.1.1, hot work operations involving cutting or welding shall be
conducted at least 35 feet from combustible materials and combustible waste, or shall
be provided with appropriate shielding to prevent sparks, slag, or heat from igniting
exposed combustibles. All other hot work operations require a minimum of 25 feet.




QUESTION 4

A fire watch must be maintained during any hot work operation. What is the minimum
duration the fire watch must continue after the conclusion of the work?

A. 15 minutes

B. 30 minutes

C. 45 minutes

D. 60 minutes

Correct Answer: B

Rationale: Per FC 2604.2.1, a fire watch shall be maintained during hot work operations,
and the fire watch shall continue for a minimum of 30 minutes after the conclusion of
the work. The commissioner or the responsible person implementing a hot work
program may extend this duration based on the hazards or work being performed.




QUESTION 5

Which Certificate of Fitness is required for a person conducting torch operations using
oxygen and a flammable gas?

, A. F-60

B. G-41

C. G-60

D. P-98

Correct Answer: C

Rationale: Per FC 2603.4.1 and the G-60 study material, torch operations using oxygen
and a flammable gas, and any torch operation for torch-applied roofing systems, shall
be performed by a G-60 Certificate of Fitness holder. The F-60 is required for fire guards
performing fire watch, not for torch operators.




QUESTION 6

True or False: An FDNY permit is required to conduct hot work using oxygen and a
flammable gas, such as acetylene or propane.

A. True

B. False

Correct Answer: A

Rationale: TRUE. Per FC 2601.2 and the G-60 study material, an FDNY permit is required
to conduct hot work using oxygen and a flammable gas. Additionally, a permit is
required for storing, using, or handling any flammable gas (e.g., LPG, CNG, or acetylene)
in excess of 400 SCF, or any oxidizing gas (e.g., oxygen) in excess of 504 SCF.

Información del documento

Subido en
10 de junio de 2026
Número de páginas
39
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$16.00

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PrimeScholars
3.2
(13)
Vendido
95
Seguidores
0
Artículos
3430
Última venta
23 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes