Examen

Computed Tomography Exam Prep

Document preview thumbnail
Vista previa 2 fuera de 5 páginas

Which of the following reduces the scatter radiation reaching the detectors? A. Post-patient collimation B. Pre-patient collimation C. Pre-detector collimation D. Both A & C -D. Both A & C Which of the following is the primary interaction between x-ray photons and tissue during computed tomography? A. Bremsstrahlung B. Characteristic C. Compton effect D. Coherent scatter -C The process by which electrons are produced at the cathode of a CT x-ray tube is known as: A. rectification B. anode heel effect C. thermionic emission D. isotropic emission -C The assignment of different generations to CT scanners is based on the configuration of the: A. patient and gantry B. tube and detectors C. anode and cathode D. tube and collimators -B When one is using a third-generation CT scanner, it is important that reference detectors positioned at the peripheral portions of the detector array be exposed to: A. homogeneous radiation B. unattenuated radiation C. monochromatic radiation D. remnant radiation -D In 1979, the scientists __________ and __________ shared the Nobel Prize for their research in computed tomography A. Watson and Crick B. Olendorf and Hounsfield C. Hounsfield and Cormack D. Hounsfield and Ambrose -C The type of compensating filter used at the x-ray tube of a CT scanner is called a: A. kernel B. water bath C. bow-tie filter D. wedge filter -C The interaction between x-ray and matter that is responsible for the production of the scatter radiation absorbed by the patient and detectors is: A. Compton effect. B. bremsstrahlung. C. photoelectric. D. characteristic -A The types of detectors used in computed tomography are: 1. Gas ionization 2. Stimulable phosphor 3. Scintillation A. 1 only B. 3 only C. 1 and 3 only D. 2 and 3 only -C Which of the following is used in gas ionization CT detectors? A. Neon B. Xenon C. Helium D. Nitrogen -B Which of the following statements concerning the translate-rotate mode of CT data acquisition is/are correct? 1. 360-degree circular detector arrays are used. 2. Data are collected only during translation. 3. Was used in first- and second-generation CT scanners. A. 2 only B. 3 only C. 1 and 2 only D. 2 and 3 only -D Which of the following terms accurately describes the type of x-ray beam used in a third-generation CT scanner? A. Pencil beam B. Fan beam C. Nutating beam D. Electron beam -B

Vista previa del contenido

Computed Tomography Exam
Prep




Which of the following reduces the scatter radiation reaching the detectors?

A. Post-patient collimation
B. Pre-patient collimation
C. Pre-detector collimation
D. Both A & C -D. Both A & C

Which of the following is the primary interaction between x-ray photons and tissue during computed
tomography?

A. Bremsstrahlung
B. Characteristic
C. Compton effect
D. Coherent scatter -C

The process by which electrons are produced at the cathode of a CT x-ray tube is known as:

A. rectification
B. anode heel effect
C. thermionic emission
D. isotropic emission -C

The assignment of different generations to CT scanners is based on the configuration of the:

A. patient and gantry
B. tube and detectors
C. anode and cathode
D. tube and collimators -B

When one is using a third-generation CT scanner, it is important that reference detectors positioned at the
peripheral portions of the detector array be exposed to:

A. homogeneous radiation
B. unattenuated radiation
C. monochromatic radiation
D. remnant radiation -D

, In 1979, the scientists __________ and __________ shared the Nobel Prize for their research in
computed tomography

A. Watson and Crick
B. Olendorf and Hounsfield
C. Hounsfield and Cormack
D. Hounsfield and Ambrose -C

The type of compensating filter used at the x-ray tube of a CT scanner is called a:

A. kernel
B. water bath
C. bow-tie filter
D. wedge filter -C

The interaction between x-ray and matter that is responsible for the production of the scatter radiation
absorbed by the patient and detectors is:

A. Compton effect.
B. bremsstrahlung.
C. photoelectric.
D. characteristic -A

The types of detectors used in computed tomography are:
1. Gas ionization
2. Stimulable phosphor
3. Scintillation

A. 1 only
B. 3 only
C. 1 and 3 only
D. 2 and 3 only -C

Which of the following is used in gas ionization CT detectors?

A. Neon
B. Xenon
C. Helium
D. Nitrogen -B

Which of the following statements concerning the translate-rotate mode of CT data acquisition is/are
correct?
1. 360-degree circular detector arrays are used.
2. Data are collected only during translation.
3. Was used in first- and second-generation CT scanners.

A. 2 only
B. 3 only
C. 1 and 2 only
D. 2 and 3 only -D

Which of the following terms accurately describes the type of x-ray beam used in a third-generation CT
scanner?

A. Pencil beam
B. Fan beam

Información del documento

Subido en
27 de mayo de 2026
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
elitenurse
4.0
(2)
Vendido
2
Seguidores
0
Artículos
309
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes