1.- Where generally *Fuel-oil is used in buildings?* What purposes?* -
✔✔✔ Correct Answer > Is used in *Stationary Equipments*,
Two purposes:
a) *Fuel Emergency Generators*
b) *Fuel Equipment used to heat the building*


2.- What *COF is required* to supervise the *Fuel-oil transfer in the
building from one floor to another?* - ✔✔✔ Correct Answer > *P-98
and maintain all qualifications and comply w/ requirements applicable
to such certificate holder*
*The P-98 COF is premise-related*


3.- The use of the word *should* refers to: - ✔✔✔ Correct Answer >
*Polices, procedures and / or best practices recommended by the
FDNY*


4.- The use of the word *shall* refers to: - ✔✔✔ Correct Answer >
*Requirement of the Fire Code or the FDNY*

,Page 2 of 50




5.- *Supervision of Fuel-Oil Piping & Storage Operation*

Shall be under the *GENERAL SUPERVISION* of P-98: - ✔✔✔ Correct
Answer > *A stationary fuel-oil storage tank, related piping, that is
installed on the lowest floor of the building and transfer fuel-oil
through piping to another stationary fuel-oil storage tank, or fuel
burning equipment, installed above such floor*


6.- *Supervision of Fuel-Oil Piping & Storage Operation*
Shall be under the *PERSONAL SUPERVISION* of P-98 COF shall be? -
✔✔✔ Correct Answer > *Periodic Inspection and Testing of tanks and
piping*


7.- *Maintenance Requirements*
Fuel-oil storage tanks and piping *shall be inspected* for any evidence
of leaks? - ✔✔✔ Correct Answer > *Weekly*


8.- *Maintenance Requirements*
Fuel-oil storage tanks *shall have their float switches tested* to
ensure that they are in good working order at least? - ✔✔✔ Correct
Answer > *Weekly*


9.- *Licences & Certificates*

,Page 3 of 50


*No* oil burning equipment *may operated until?* - ✔✔✔ Correct
Answer > a) *Certificate of Compliance* has been issued by
*NYCDOB*
b) *Air pollution control code* requirements *NYCDEP*
c) *Permit for the Storage & use of fuel-oil* issued by *FDNY*


10.- *Licences & Certificates*
Pursuant to the *New NYC Fire Code & Mechanical Codes* stated
that? - ✔✔✔ Correct Answer > *The COF is required for all existing
and new buildings where fuel is being transported from the lowest
levels to tanks or equipment on upper floors*


11.- *Oil Circulation in the System*
Diagram of:
*Oil Circulation from the Tank at the LOWEST floor of a building to the
burner on the floor above such floor through the pump* - ✔✔✔
Correct Answer >


12.- *Oil Circulation in the System*

What the *oil storage tank* do? - ✔✔✔ Correct Answer > *Provides
the supply of oil for combustion in the oil burner. It's inside a dike. In
case of leak the diked area will contain the oil.*

, Page 4 of 50


13.- *Oil Circulation in the System*

How is the #2 fuel-oil in its *normal condition*? - ✔✔✔ Correct
Answer > *Is thin and light and is easily pumped through the
circulation system.*


14.- *Oil Circulation in the System*

*What the suction pump do?* - ✔✔✔ Correct Answer > *Circulates
the oil throughout the system. Dirt and sediment are present in the
fuel-oil coming from the oil storage tank. The oil filter removes most
of these contaminants from the oil before the oil reaches the burner's
strainer.*


15.- *Oil Circulation in the System*

How many inches has to be the *SUCTION LINE?* - ✔✔✔ Correct
Answer > *6 inches from the bottom of the tank for sediments not to
be absorbed*


16.- *Oil Circulation in the System*

What is the *vacuum gauge?* - ✔✔✔ Correct Answer > *A device that
measures pressure below atmospheric pressure.*


17.- *Oil Circulation in the System*

Información del documento

Subido en
13 de mayo de 2026
Número de páginas
50
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$27.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
LectTutor
3.8
(62)
Vendido
376
Seguidores
126
Artículos
6374
Última venta
2 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes