How quickly should PJM members implement emergency procedures? ✔Correct Answer-
Immediately

When in desired relief expected after members are notified of any emergency procedures?
✔Correct Answer-Within 30 minutes

What system is used to issue NERC Energy Emergency Alerts? ✔Correct Answer-The Reliability
Coordinators Information System (RCIS)

What does an EEA Level 1 indicate? ✔Correct Answer-That all available resources are in use
OR

There is concern about being able to sustain required Contingency Reserves.

PJM will issue EEA Level 1 at the same time they issue: ✔Correct Answer-When they issue a
Maximum Generation Emergency Alert

What does EEA Level 2 indicate? ✔Correct Answer-That a control area foresees or has
implemented procedures up to but excluding interruption of firm load commitments (e.g. public
appeals, voltage reduction, load management, interruption of non-firm contracts)

PJM will issue EEA Level 2 at the same time as: ✔Correct Answer-When they implement an
Emergency Mandatory Load Management Reduction Action, a Voltage Reduction Action or a
Deploy All Resources Action. Whichever comes first.

What does EEA Level 3 indicate? ✔Correct Answer-That firm load interruption is imminent or
in progress

What will have taken place prior to EEA Level 3 being declared? ✔Correct Answer-1. All
generation online regardless of cost
2. All purchases made regardless of cost
3. All non-firm sales recalled
4. All contractually interruptible load curtailed

When does PJM issue EEA Level 3? ✔Correct Answer-When they implement a Manual Load
Dump Action

What is the reliability requirement for synchronized reserves? ✔Correct Answer-Synchronized
reserves: Largest single contingency

, What is the reliability requirement for primary reserves? ✔Correct Answer-Primary Reserves:
150% of synchronized reserve requirement

What is the reliability requirement for operating reserves? ✔Correct Answer-Operating
Reserves: Greater of primary reserve requirement, 3,000 MW or largest active gas contingency

What is the purpose of Unit Start Up Notification Alert? ✔Correct Answer-Tell members to
prepare units so that they can be brought online within 48 hours in anticipation of a shortage of
operating capacity, stability issues or constrained ops

What is the trigger for the Unit Start Up Notification Alert? ✔Correct Answer-A reliability
assessment determines that long lead time generation will be needed in the future

What is the maximum "time to start" reportable in the PJM Markets Gateway? ✔Correct
Answer-6 days

What is the purpose of the Maximum Generation/Load Management Alert? ✔Correct
Answer-To provide an early alert that system conditions may require the use of the PJM
Emergency Procedures

What is the trigger for a Maximum Generation/Load Management Alert to be issued?
✔Correct Answer-When Maximum Generation Emergency is called into the operating capacity,
or if Demand Response is projected to be implemented. Or if the operating reserve requirement
is greater than scheduled operating reserve

What should members do when a max gen/load management alert is issued? ✔Correct
Answer-See if any maintenance that might be scheduled can be deferred. Report any
fuel/environmental limited facilities

What is the purpose of the Primary Reserve Alert? ✔Correct Answer-Alert members of the
anticipated shortage of operating reserve capacity

What is the trigger for a Primary Reserve Alert? ✔Correct Answer-When the estimated
operating reserve capacity is less than the forecasted primary reserve requirement

What should members do when a primary reserve alert is issued? ✔Correct Answer-See if any
maintenance that might be scheduled can be deferred. Report any fuel/environmental limited
facilities

What is the purpose of a Voltage Reduction Alert? ✔Correct Answer-To alert members that a
voltage reduction action may be required. They will provide the estimated hour of
implementation when the alert is issued.

Información del documento

Subido en
21 de abril de 2026
Número de páginas
11
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyclub
3.6
(14)
Vendido
64
Seguidores
1
Artículos
12620
Última venta
4 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes