• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 3 fuera de 16 páginas
Examen

Hvac Epa 608 Certification Exam Epa 608

Document preview thumbnail
Vista previa 3 fuera de 16 páginas

HVAC EPA 608 CERTIFICATION EXAM EPA 608

Vista previa del contenido

1|Pag e




HVAC EPA 608 CERTIFICATION EXAM|| EPA 608
HVAC CERTIFICATION TEST WITH ALL
QUESTIONS AND 100% CORRECT ANSWERS
ALREADY GRADED A+|| LATEST AND
COMPLETE UPDATE 2026-2027 WITH EXPERT
VERIFIED SOLUTIONS|| ASSURED PASS!!!

Are there drop-in replacements for R-12 systems? Why or why not? ✔ No because
the new refrigerants are incompatible with the oils and lubricants used in R-12
systems.



What type of oil is used in R-134a and what oils will it mix with? ✔ Ester based
oils and they do not mix with other oils



What type of lubricant is used with HCFCs? ✔ Alkylbenzene lubricant



What is difference b/w ternary blend a azeotropic blend? ✔ Ternary blends are
three-part mixtures whereas azeotropic blends are blends of two or more
compounds that act like a single compound.



What is the trait of a hygroscopic lubricant? ✔ It absorbs (takes on) moisture

,2|Pag e




What is temperature glide and what type of blend won't have it? ✔ Temp. blend is
the difference between the dew point and the bubble point


Under what circumstances can recovered refrigerant be used? ✔ It may be
returned to the appliance from which it was removed or to another appliance
owned by the same person without being recycled or reclaimed, unless the
appliance is an MVAC or MVAC-like appliance


Where should you remove the refrigerant in a system that has a condenser below
the receiver? ✔ Condenser outlet


How must you recover refrigerant from a parallel system? Why? ✔ Isolate a
parallel compressor system in order to recover refrigerant. Failure to isolate a
parallel compressor system will cause an open equalization that will prevent
refrigerant recovery


Where do leaks commonly occur in low pressure systems? What about open-drive
type compressor systems? ✔ Leaks in gaskets or fittings. The SHAFT SEAL in
open-drive compressor low pressure refrigeration systems is particularly
susceptible to leaks


Does refrigerant go out of the system in low pressure or does air and moisture go
in? Why? ✔ A low-pressure system operates in a vacuum (below atmospheric
pressure) to enter the refrigeration system.

, 3|Pag e




When should a low pressure system be leaked checked according to ASHRAE
guideline 3-1996? ✔ If the pressure in system rises from 1 mm Hg to a level above
2.5 mm Hg during vacuum testing



What does a purge unit do and what is a high efficiency purge unit? ✔ The purge
unit prevents the accumulation of non-condensable substances (air and moisture)
in order to keep the system clean and maintain efficiency: The purge unit removes
air and moisture to prevent reduced condenser surface area, increased head
pressure, compressor surge, increased pressure differential, and system corrosion.
A high efficiency purge system will expel very little refrigerant along with the air.



How does a centrifugal purge unit work? ✔ A centrifugal purge unit takes its
suction from the top of the condenser, removes the air from the system, and
returns the refrigerant to the evaporator.


What are three visible ways to check for leaks in a low pressure system?

✔ Excessive running of a purge system, continuous excessive moisture in the
purge unit could indicate a leak in the condenser or the chiller barrel, high lead
pressure.



What needs to be done to leak check a low pressure system? ✔ Increase the
pressure in the system by use of controlled hot water or heater blankets.

Información del documento

Subido en
12 de abril de 2026
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
LeeErickson
1.5
(2)
Vendido
13
Seguidores
1
Artículos
3624
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes