2



TN BC Contractors exam with accurate detailed solutions
|| || || || || || ||




After installation and adequate fastening, floor decks serve several purposes:
|| || || || || || || || ||




A. Acts as a working platform
|| || || || ||




B. Stabilizes the frame
|| || ||




C. Serves as concrete form for the slab
|| || || || || || ||




D. All the above - ✔✔Steel Deck pg 6:
|| || || || || || || || ||




D. All the above
|| || ||




Composite floor deck is normally installed so the __________________ - ✔✔Steel Deck pg
|| || || || || || || || || || || || ||




6:
||




Panel ends do not overlap || || || ||




Roof deck is not designed to act compositely with other materials. The roof
|| || || || || || || || || || || || ||




deck________________________ - ✔✔Steel Deck pg 7: || || || || ||




Acts alone in transferring horizontal and vertical loads into the building frame.
|| || || || || || || || || || ||




Roof deck is typically installed to end lap approximately _________ inches over supports. -
|| || || || || || || || || || || || || ||




✔✔Steel Deck pg 7: || || ||




2"



___________________ can be used in the same manner as floor deck. Electrical, telephone || || || || || || || || || || || || ||




and computer wires are easily run through the chase created between the deck panel and
|| || || || || || || || || || || || || || ||




the bottom sheet. - ✔✔Steel Deck pg 8:
|| || || || || || ||




Cellular Deck ||

,2


A 3' x 12" composite floor deck will have a nominal thickness range of. 03 inches to. 06
|| || || || || || || || || || || || || || || || || ||




inches and a weight range of ____ to _____ psf - ✔✔Steel Deck pg 9:
|| || || || || || || || || || || || || ||




2 to 4 psf
|| || ||




F deck may also be referred to as______________ for the name,. 03 inches two. 06 inches
|| || || || || || || || || || || || || || || ||




for the thickness and 2 to 4 PSF for the weight. - ✔✔Steel Deck pg 10:
|| || || || || || || || || || || || || || ||




1 1/2" X 6" Intermediate Rib
|| || || || ||




The weight range for cellular floor decking is__________ - ✔✔Steel Deck pg 12:
|| || || || || || || || || || || ||




4 to 7 PSF
|| || ||




A heavy duty form decks name used in centering is______ Form deck with a thickness
|| || || || || || || || || || || || || || ||




of_____ to _____ And a weight range of one to two PSF - ✔✔Steel Deck pg 11:
|| || || || || || || || || || || || || || || ||




15/16" and 0.017" to 0.040" || || || ||




Steel deck is banded into bundles that can weigh several thousand pounds but the deck
|| || || || || || || || || || || || || || ||




bundle weight will be limited to a maximum of_______________ For deck to be applied to
|| || || || || || || || || || || || || || ||




joists. - ✔✔Steel Deck pg 14: || || || || ||




4000 lbs ||




If ground storage is needed, the deck bundles should be______________ - ✔✔Steel Deck pg
|| || || || || || || || || || || || ||




18:
||




Stored off the ground, with one end elevated to provide drainage.
|| || || || || || || || || ||




Deck bundles must________ be placed on the frame near a main supporting beam at a
|| || || || || || || || || || || || || || ||




column or a wall - ✔✔Steel Deck pg 18: || || || || || || || ||




ALWAYS

,2


Bundles should be landed so that the ___________________________ rather than having
|| || || || || || || || || || ||




one or both ends cantilevered. - ✔✔Steel Deck pg 22:
|| || || || || || || || ||




Ends of the bundles rest on a bearing surface
|| || || || || || || ||




Are you working area should be at least _________ feet wide. - ✔✔Steel Deck pg 24:
|| || || || || || || || || || || || || || ||




12



When aligning the edge (side) lap, the worker should__________ - ✔✔Steel Deck pg 25:
|| || || || || || || || || || || || ||




Kneel



Deck fastening to the structural frame can be accomplished with: - ✔✔Steel Deck pg 28:
|| || || || || || || || || || || || || ||




Welds, self drilling screws, air driven, and power driven
|| || || || || || || ||




Screws are typically_____ or ________ With a special drill point when used to attach
|| || || || || || || || || || || || || ||




decking. - ✔✔Steel Deck pg 30: || || || || ||




#12s or 1/4" in diameter
|| || || ||




Weld washers are not recommended for deck thickness of_____ (Minimum of 22 gauge)
|| || || || || || || || || || || || ||




and greater - ✔✔Steel Deck pg 32:
|| || || || || ||




0.028"



A good weld will have______ Or more of its perimeter working. - ✔✔Steel Deck pg 34:
|| || || || || || || || || || || || || || ||




75% (7/8ths previously)
|| ||




Welding side laps is not recommended for decks type____ Or lighter (0.028" min.) -
|| || || || || || || || || || || || || ||




✔✔Steel deck pg 34: || || ||




22

, 2




Weld washers should___________ Be used at side laps between supports - ✔✔Steel deck pg
|| || || || || || || || || || || || || ||




34:

Never



No reinforcing is generally required for an opening of 6 inches as long as not more
|| || || || || || || || || || || || || || || ||




than____ webs are removed - ✔✔Steel Deck pg 37: || || || || || || || ||




2



For holes or dents greater than a rib (8 inches to 13 inches), It is advisable to use
|| || || || || || || || || || || || || || || || || ||




a____________ to cover it - ✔✔Steel Deck pg 38: || || || || || || || ||




0.057" minimum plate || ||




The deck should have been selected to provide at least___________ pounds per square foot
|| || || || || || || || || || || || || ||




capacity as a working platform. - ✔✔Steel Deck pg 43:
|| || || || || || || || ||




50



If the deck is to act as a diaphragm during construction, it must be realize that the
|| || || || || || || || || || || || || || || || ||




diaphragm is not effective until all deck units are_______________ - ✔✔Steel Deck pg 43:
|| || || || || || || || || || || || ||




Placed and fully connected || || ||




A chimney shall extend at least how many feet higher than any portion of a building within
|| || || || || || || || || || || || || || || || ||




10 feet? ||




A. 2' ||




B. 3' ||




C. 5' ||




D. 6' - ✔✔IBC pg 444
|| || || || ||

Información del documento

Subido en
10 de abril de 2026
Número de páginas
53
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$24.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Ruiz
3.2
(15)
Vendido
106
Seguidores
4
Artículos
14206
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes