1. Which of the following devices is used to detect smoke using a
light-scattering principle?
A. Ionization smoke detector
B. Beam detector
C. Photoelectric smoke detector
D. Heat detector

Photoelectric smoke detectors use a light source and a photodetector
to sense smoke particles scattering light. This method is effective for
detecting smoldering fires.

2. What is the primary purpose of a fire alarm control panel (FACP)?
A. To supply power to the building
B. To regulate sprinklers
C. To monitor and control fire alarm initiating devices and

, notification appliances
D. To detect gas leaks

The FACP serves as the central hub of a fire alarm system, monitoring
initiating devices such as smoke and heat detectors and activating
notification appliances when needed.

3. Which type of initiating device is most suitable for areas prone to
rapid flaming fires?
A. Ionization smoke detector
B. Heat detector
C. Photoelectric smoke detector
D. Duct detector

Heat detectors respond to high temperatures and rapid rises in
temperature, making them ideal for detecting fast-flaming fires.

4. Which signaling method is typically used for transmitting signals
from a fire alarm control panel to a remote monitoring station?
A. Wireless RF only
B. Telephone line or IP-based communication
C. Local horn/strobe only
D. Audio speaker network

,Remote monitoring of fire alarm systems usually occurs via telephone
circuits or IP networks to ensure immediate response from a central
monitoring station.

5. A duct smoke detector is installed to:
A. Detect smoke in open areas
B. Detect smoke within HVAC ductwork
C. Activate sprinkler systems
D. Monitor heat in a kitchen

Duct smoke detectors monitor the airflow within heating, ventilation,
and air conditioning ducts to prevent smoke from circulating through
the building.

6. Which fire alarm notification appliance is required to provide both
audible and visible alerts in areas with hearing-impaired
occupants?
A. Horn
B. Bell
C. Horn/strobe combination
D. Chime

Areas with hearing-impaired occupants must use notification
appliances that include visual alerts, typically a strobe, along with
audible devices.

, 7. What is the primary difference between a Class A and Class B fire
alarm circuit?
A. Voltage rating
B. Current rating
C. Circuit continuity in the event of a single open or short
D. Number of devices

Class A circuits provide a path back to the control panel if the wiring is
broken, maintaining circuit integrity, whereas Class B circuits do not.

8. Which standard specifies the installation requirements for fire
alarm systems in the United States?
A. NFPA 13
B. NFPA 72
C. NFPA 70
D. UL 864

NFPA 72, the National Fire Alarm and Signaling Code, sets the
standards for the design, installation, and maintenance of fire alarm
systems.

9. What is the main advantage of using an addressable fire alarm
system over a conventional system?
A. Lower installation cost
B. Individual device identification and status monitoring

Información del documento

Subido en
10 de abril de 2026
Número de páginas
41
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$23.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Chiriz
4.0
(3)
Vendido
21
Seguidores
5
Artículos
3864
Última venta
5 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes