FDNY A35 (Latest 2026) Real Questions
and Answers 100% Correct (verified)
• The Cooling System -✓✓The cooling system should be tested every 6 months to make
sure that it is working correctly.
The water supply control valves should always be open when the air compressor is in
operation.

• The Air Intake system -✓✓The air intake filter should be inspected and cleaned
weekly. It should be replaced every 6
months. If at any time the filter is damaged it should be replaced.

• The lubrication Oil -✓✓The Certificate of Fitness holder should refer to the
manufacturer's manual to determine the safe
operating temperatures of the lubrication oil. The level of the lubricating oil (lube oil)
should be
checked weekly using the dipstick. The lube oil is designed to lubricate the moving parts
on the
air compressor. The oil used must be of the grade specified by the compressor
manufacturer.
The lube oil should be replaced every six months.

• The Automatic low-level Inidicator -✓✓The automatic low-level oil indicator switch
should be tested every 3 months. This is tested by
manually draining the oil from the air compressor when it is running. The indictor switch
will
shut down the air compressor within a few minutes if it is working correctly. When
testing the
compressor in this way, do not run the air compressor for a long period of time. If the
switch is
defective, it should be repaired or replaced. The air
compressor should be refilled with oil before it is used again.

• The air receiver -✓✓Water builds up in the moisture separator assembly and the air
receiver must be drained daily;
however, there is one exception. Do not drain moisture from the air compressor when
the
ambient temperature drops below 40 degrees Fahrenheit. This is done by opening the
drain
valve and draining off the excess water. All safety valves should be manually operated
every
week. This is to ensure that they will function correctly in case of an emergency. It is
recommended that the air receiver tank be pressure tested at a minimum of every 5
years by a

Información del documento

Subido en
10 de abril de 2026
Número de páginas
3
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PACKPASS
3.7
(7)
Vendido
55
Seguidores
2
Artículos
8092
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes