nicet #3 Question and answers 100% correct 2025/2026 Obstruction investigations should be recommended when which three situations occur? (Choose three.) after extended period of being shut down and returned to service drains or inspector tests plugged by foreign material lack of regular inspections obstructive material observed during drain test - correct answer abd Which of the following steps need to be performed by the impairment coordinator if impairment will keep a system out of service for more than 10 hours in a 24-hour period? evacuation of the building or portion of the building affected by the system out of service, establishment of a temporary water supply, establishment of an approved fire watch inform the owner of the responsibility to make appropriate repairs to the system the property owner or designated representative, insurance carrier, alarm company, and other authorities have been advised that protection has been restored a tag shall be posted at each fire department connection and the system control valve, and other locations required by the Authority Having Jurisdiction (AHJ), indicating which system, or part thereof, has been removed from service - correct answer a

Vista previa del contenido

nicet #3 Question and answers 100%
correct 2025/2026
Obstruction investigations should be recommended when which three situations occur? (Choose three.)

after extended period of being shut down and returned to service

drains or inspector tests plugged by foreign material

lack of regular inspections

obstructive material observed during drain test - correct answer ✔abd



Which of the following steps need to be performed by the impairment coordinator if impairment will
keep a system out of service for more than 10 hours in a 24-hour period?

evacuation of the building or portion of the building affected by the system out of service, establishment
of a temporary water supply, establishment of an approved fire watch

inform the owner of the responsibility to make appropriate repairs to the system

the property owner or designated representative, insurance carrier, alarm company, and other
authorities have been advised that protection has been restored

a tag shall be posted at each fire department connection and the system control valve, and other
locations required by the Authority Having Jurisdiction (AHJ), indicating which system, or part thereof,
has been removed from service - correct answer ✔a



The owner of a property being inspected asks for verification that the racks being added will be
adequately protected by the existing system, because the type of storage has not changed.What should
be done?

agree with the owner because the commodity has not changed

tell the owner that larger pipe sizes are needed to adapt for the new racks

tell the owner that sprinklers need to be installed in the racks

tell the owner to contact an engineer to evaulate the changes since verifying the adequacy of the system
design falls outside the scope of NFPA 25 - correct answer ✔d

, Before servicing a dry system air compressor, which device could be used to safely determine that
power is not being supplied to the compressor?

fire alarm control panel

refractometer

RPM meter

voltage meter - correct answer ✔d



How often does the interior of a water storage tank, which was protected from corrosion, require
inspection?

monthly

annually

3 years

5 years - correct answer ✔d



According to NFPA 25, what is the minimum information required to be present on a sign attached to a
system control valve?

the fire alarm module number associated with it

the system or portion of the system it controls

the type of control valve it is and year of manufacture

the year it was first placed in service and each date it received service thereafter - correct answer ✔b



According to NFPA 25, what is the typical size of an impairment tag?

2 inches x 4 inches

3 inches x 5 inches

4 inches x 6 inches

5 inches x 7 inches - correct answer ✔c

Información del documento

Subido en
4 de abril de 2026
Número de páginas
13
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
flyhigher329
3.7
(61)
Vendido
386
Seguidores
175
Artículos
18525
Última venta
1 semana hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes