CRCST Exam Prep Practice Exercise 1 Questions With 100% Pass /. Dynamic air removal: exposure time for any wrapped item at 275 degrees. - Answer-3 minutes /.What is the correct percentage of relative humidity for steam sterilization? - Answer-97%-100% /.What are the 4 cycles of steam sterilization? - Answer-Conditioning, exposure, exhaust, drying /.Which low-temp sterilization method requires monitoring? - Answer-Ethylene oxide /.How does ethylene oxide kill microbes? - Answer-By a process called alkylation. /.How do ozone and hydrogen peroxide kill microbes? - Answer-By a process called oxidation. /.Discuss sterilization parameters for ethylene oxide (concentration, temp, humidity, exposure time, aeration time) - Answer-Concentration: 450-1200 mg/l Temp: 98-145 degrees F Exposure time: 1-6 hours Humidity: 40-80% Aeration time: 8-12 hours at 122-140 degrees F /.What is the microorganism of choice for ethylene oxide sterilization? - Answer-Bacillus atrophaeus /.What are the five phases of gas plasma sterilization? - Answer-Vacuum, injection, diffusion, plasma, vent /.Which materials are not recommended for use in hydrogen peroxide sterilization method She? - Answer-Cellulose, muslin wraps /.What is the microorganism of choice for hydrogen peroxide gas plasma sterilization? - Answer-Geobacillus stearothermophilus /.Discuss hydrogen peroxide gas plasma sterilization parameters (time, temp, concentration, vacuum level, plasma) - Answer-Time: 24-75 minutes Temp: less than 131 degrees F Concentration: 59-95% Vacuum level: auto controlled Plasma: auto controlled /.What are the 4 cycles for vaporized hydrogen peroxide systems? - Answer-Conditioning, leak test, sterilization, aeration /.Discuss vaporized hydrogen peroxide sterilization parameters (temp, concentration, time, other). - Answer-Temp: less than 122 degrees F Concentration: 59% Time: 28-55 minutes Other: preset cycles /.What is the microorganism of choice for VHP? - Answer-Geobacillus stearothermophilus /.Discuss ozone sterilization parameters (temp, concentration, humidity, time). - Answer-Temp: 87.4-97 degrees F Concentration: 59% Humidity: 85-100% Time: 4.5 hours /.What is the microorganism of choice for OzOne sterilization? - Answer-Geobacillus stearothermophilus /.What materials cannot be processed in VHP or gas plasma sterilizers? - Answer-Cellulose, linens, liquids, powders /.What materials cannot be processed in an ozone sterilizer? - Answer-Rubber, latex, textiles, copper, brass, bronze, zinc, nickel. /.How many air exchanges are required in the decontamination area? - Answer-No less that 10 per hour. /.What are the parameters for relative humidity in the decontamination area? - Answer-30-60% /.What should the temperature range be in the decontamination are? - Answer-60-65 degrees F /.What is the temperature range for water in the decontamination area? - Answer-80-110 degrees F /.This temperature should not be exceeded when using enzymatic cleaners. - Answer-140 degrees F /.What is the pH of neutral detergents? - Answer-6-8

Vista previa del contenido

CRCST Exam Prep Practice Exercise 1
Questions With 100% Pass

/. Dynamic air removal: exposure time for any wrapped item at 275 degrees. - Answer-3
minutes

/.What is the correct percentage of relative humidity for steam sterilization? - Answer-
97%-100%

/.What are the 4 cycles of steam sterilization? - Answer-Conditioning, exposure,
exhaust, drying

/.Which low-temp sterilization method requires monitoring? - Answer-Ethylene oxide

/.How does ethylene oxide kill microbes? - Answer-By a process called alkylation.

/.How do ozone and hydrogen peroxide kill microbes? - Answer-By a process called
oxidation.

/.Discuss sterilization parameters for ethylene oxide (concentration, temp, humidity,
exposure time, aeration time) - Answer-Concentration: 450-1200 mg/l
Temp: 98-145 degrees F
Exposure time: 1-6 hours
Humidity: 40-80%
Aeration time: 8-12 hours at 122-140 degrees F

/.What is the microorganism of choice for ethylene oxide sterilization? - Answer-Bacillus
atrophaeus

/.What are the five phases of gas plasma sterilization? - Answer-Vacuum, injection,
diffusion, plasma, vent

/.Which materials are not recommended for use in hydrogen peroxide sterilization
method She? - Answer-Cellulose, muslin wraps

/.What is the microorganism of choice for hydrogen peroxide gas plasma sterilization? -
Answer-Geobacillus stearothermophilus

/.Discuss hydrogen peroxide gas plasma sterilization parameters (time, temp,
concentration, vacuum level, plasma) - Answer-Time: 24-75 minutes
Temp: less than 131 degrees F
Concentration: 59-95%

, Vacuum level: auto controlled
Plasma: auto controlled

/.What are the 4 cycles for vaporized hydrogen peroxide systems? - Answer-
Conditioning, leak test, sterilization, aeration

/.Discuss vaporized hydrogen peroxide sterilization parameters (temp, concentration,
time, other). - Answer-Temp: less than 122 degrees F
Concentration: 59%
Time: 28-55 minutes
Other: preset cycles

/.What is the microorganism of choice for VHP? - Answer-Geobacillus
stearothermophilus

/.Discuss ozone sterilization parameters (temp, concentration, humidity, time). - Answer-
Temp: 87.4-97 degrees F
Concentration: 59%
Humidity: 85-100%
Time: 4.5 hours

/.What is the microorganism of choice for OzOne sterilization? - Answer-Geobacillus
stearothermophilus

/.What materials cannot be processed in VHP or gas plasma sterilizers? - Answer-
Cellulose, linens, liquids, powders

/.What materials cannot be processed in an ozone sterilizer? - Answer-Rubber, latex,
textiles, copper, brass, bronze, zinc, nickel.

/.How many air exchanges are required in the decontamination area? - Answer-No less
that 10 per hour.

/.What are the parameters for relative humidity in the decontamination area? - Answer-
30-60%

/.What should the temperature range be in the decontamination are? - Answer-60-65
degrees F

/.What is the temperature range for water in the decontamination area? - Answer-80-
110 degrees F

/.This temperature should not be exceeded when using enzymatic cleaners. - Answer-
140 degrees F

/.What is the pH of neutral detergents? - Answer-6-8

Información del documento

Subido en
30 de marzo de 2026
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Brainariam
3.4
(30)
Vendido
160
Seguidores
7
Artículos
8386
Última venta
2 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes