• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 3 fuera de 21 páginas
Examen

DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026

Document preview thumbnail
Vista previa 3 fuera de 21 páginas

DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026 DC 3rd class stationary steam engineer license prep| With complete solution| RATED A+ | 2026

Vista previa del contenido

DC 3rd class sta onary steam engineer license prep|
With complete solu on| RATED A+ | 2026

_________ are necessary for complete combus on

me, temperature, mixture, and atomiza on

if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______

214.7

a boiler is opera ng at 400 PSI, and the safety valve opens at 410 PSI and closes at 398 PSI. The
blowdown is______psi

12

an oil cooler is commonly used with a(n) ________ when opera ng in conjunc on with a turbo-
generator

steam turbine

a boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a steam temperature of
500 degrees Fahrenheit. The steam produced is _______ steam

superheated

the economizer on a boiler is used to _______

add heat to the feed water

blowers are normally used with________ boilers

water tube

overhea ng of tubes on a boiler can be caused by________

scale on tubes

carbon dioxide in a condensate return system causes_________

channeling

a ________ pump is a posi ve displacement pump

reciproca ng

,a boiler genera ng 6000 lb of steam/hr produces _______btu/hr

6,000,000

a bo2om blowdown is performed on a boiler to _____

discharge sludge and sediment

water columns are connected to the boiler with a minimum of _______" pipe

1

the minimum size of a water column blowdown valve is_______".

3/4

the maximum size bo2om blowdown valve on a boiler is_________".

2 1/2

a ________ allows condensate to pass through, but stops Steam.

a steam trap

when taking over a shi5, the first thing to do is check the________

water level in each boiler

according to the asme code, a high-pressure boiler having more than 500 square feet of hea ng
surface shall have________

two or more safety valves

the probable cause of an increase in temperature of gases of combus on at the boiler Outlet
is____

dirty hea ng services

boilers in ba2ery equipped with________ must have two main steam stop valves and a free-
flowing drain between them

manhole openings

in order to be sure the gauge glass is indica ng an accurate water level reading, the sta onary
engineer should______

blowdown the gauge glass

a con nuous blowdown line is located___

, in the Steam and water drum well below the nowl

a temperature reading of 80 degrees Celsius is equal to_________°f

176

a chimney temperature of 250 degrees Fahrenheit above steam temperature indicates_______

poor efficiency

a manometer is red in________

inches of water

the boiling point of water will____ with an increase in pressure

be raised

if a lather is not obtained when performing a soap hardness test, the water sample is_______

hard

combus on efficiency can be increased when air is________

preheated

______ dra5 is produced by a fan located between the boiler and the chimney

induced

the overspeed trip on a steam turbine should be tested ______

before pu=ng the steam turbine on-line

a high CO2 reading in the gases of combus on is a sign of____

High combus on efficiency

the purpose of chemically trea ng feedwater is to________

turn scale-forming salts to a non adhering sludge

water in a d ra ng feed water heater is prevented from entering the steam line by a(n) _______.

Loop seal or internal overflow

a steam turbine opera ng at 3600 RPM will trip at_________ rpm

3960

he steam line going to The Blowers is connected to the main ________

Información del documento

Subido en
5 de marzo de 2026
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STUVEX
3.8
(123)
Vendido
834
Seguidores
314
Artículos
16233
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes