AAB MT BASIC KNOWLEDGE QUESTIONS
WITH 100% CORRECT ANSWERS
What agency approves new test methodologies, instruments, and reagents before they are available for
purchase by consumers? - correct answer -FDA

How often should biological safety hoods be inspected? - correct answer -Annually

What is the minimum number of standards required for a standard curve? - correct answer -3

What is the maximum magnification using a brightfield microscope? - correct answer -1000X

What is the most accurate pipette for reconstituting control material? - correct answer -Glass volumetric
pipettes

Which unit of measure refers to 10^-3? - correct answer -Milli-

What is the calculated cholesterol/HDL ratio given the following results?
Cholesterol 225 mg/dL
HDL 75 mg/dL - correct answer -225/75= 3.00

200 microliters of patient serum is diluted with 800 microliters of saline. What is the final dilution? -
correct answer -1:5

What is the calculated LDL cholesterol given the following lipid profile results?
Triglycerides 190 mg/dL
Cholesterol 225 mg/dL
HDL 75 mg/dL - correct answer -LDL = Total cholesterol - HDL - (TG/5)
112 = 225 - 75 - (190/5)

How is relative centrifugal force calculated? - correct answer -1.18 x 10^-5 x r x rpm^2

A chain of custody is required for all of the following: - correct answer -Legal blood alcohol, pre-
employment drug screen, and paternity testing

A chain of custody is required for all of the following, EXCEPT: - correct answer -Fetal fibronectin

What federal legislation regulates most clinical laboratories? - correct answer -Clinical Laboratory
Improvement Amendments (CLIA)

What is the level of complexity of most testing performed in clinical laboratories? - correct answer -
Moderately complex

How often does CLIA require clinical laboratories to have inspections? - correct answer -Every 2 years

, Which laboratories are NOT required to participate in proficiency testing? - correct answer -Laboratories
performing waived testing only.

Which proficiency testing (PT) results do not meet the CLIA performance criteria? - correct answer -
Failed the same analyte in two consecutive PT events

Which one of the following is an example of alternate proficiency testing? - correct answer -Split
samples sent to another facility using the same test method.

All of the following are pre-analytical errors except which one? - correct answer -Transcription error
entering a manual result

All of the following are pre-analytical erros: - correct answer -Ordering a lab test under the wrong
patient number, misidentification of a patient, mislabeling an add-on test

Which one of the following is the most common analytical error? - correct answer -Not checking
specimen integrity

What is the most common post-analytical error? - correct answer -Clerical errors

How often must a procedure be reviewed? - correct answer -Annual review is required

How often must thermometers be checked against the NIST thermometer? - correct answer -Annually

In which manual are the directions for running quality control for a specific assay kept? - correct answer
-Operating procedure manual

Following equipment maintenance, when is quality control suggested? - correct answer -After any
preventative maintenance

What is the most common reason for a control value to be outside of 3SD? - correct answer -Random
error

If one control is outside the 95% confidence limits, then what is the most appropriate remedial action to
take initially? - correct answer -Repeat the same control

Where should an unopened container of methanol be stored? - correct answer -Flammable safety
cabinet

After preventative maintenance by field service, which one of the following is recommended? - correct
answer -Verification of QC results

According to CLIA, who is responsible for specimen processing, test performance, and reporting test
results? - correct answer -Testing personnel

Which one of the following is NOT a job duty of the testing personnel? - correct answer -Interpretation
of highly complex testing

Información del documento

Subido en
4 de marzo de 2026
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyglobal
4.0
(11)
Vendido
30
Seguidores
0
Artículos
2761
Última venta
4 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes