Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

Nicet Level 1 water based systems

Puntuación
-
Vendido
-
Páginas
6
Grado
A+
Subido en
02-03-2026
Escrito en
2025/2026

Nicet Level 1 water based systems

Institución
Fire Technology
Grado
Fire technology

Vista previa del contenido

Nicet Level 1 water based systems exam
with correct answers revised and
verified.
What is a purpose of a control valve
Control Flow to water based fire protection system
The gauge on the quick opening device shall indicate _____ as compared to the
gauge on the system side of the dry pipe valve?
the same pressure
What type of test shall be provided when a valve is returned to service to determine
that the valve is open?
Valve status test
What is a fire service main?
A pipe and its appurtenances on private property/ Pipe between a source of water
and the base of the system riser
Name the system that utilizes a plate through which a passes a specific amount of
foam concentrate at a specific pressure.
Orifice Plate Proportioning
During an inspection, which of the following would be identified as a sprinkler
which shall be replaced?
Corrosion
What are the inspection requirements for hangers and seismic braces installed in
concealed spaces?
Periodic inspection is not required
Gauges shall be replaced every _____ or tested every _____ by comparison with a
calibrated gauge
5 years/ 5 years

, Sprinklers are subject to overspray accumulation shall be protected using
cellophane bags having a thickness of ______?
0.0003 inches
A building has 3 different types of sprinklers. How many sprinkler wrenches are
required to be kept on premises?
3
During testing of a diesel engine driven fire pump system. The fire pump is
running at a low RPM. This is considered a _________?
Impairment




Where air pressure supervision is connected to a constantly attended location
gauges shall be inspected ______?
Monthly
Sprinklers installed in areas that are inaccessible for safety consideration, due to
process operations ____ be ____ during each scheduled shutdown?
Shall/ Inspected
What type of valve is designed for the purpose of reducing downstream water
pressure under both residual and static conditions
Pressure reducing valve
PIV and OS&Y shall be backed a __________ from the fully open position to
prevent jamming.
1/4 turn
Gauges not accurate to within _______ percentage of the full scale shall be
recalibrated or replaced?
3 percent

Escuela, estudio y materia

Institución
Fire technology
Grado
Fire technology

Información del documento

Subido en
2 de marzo de 2026
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$23.53
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
smithclaggercole

Conoce al vendedor

Seller avatar
smithclaggercole WINSCOIN
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2
Miembro desde
8 meses
Número de seguidores
0
Documentos
136
Última venta
3 meses hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes