• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 127 páginas
Examen

EFM CERTIFICATION EXAM 3 CERTIFICATION EVALUATION 2026 FULL QUESTIONS WITH SOLUTIONS

Document preview thumbnail
Vista previa 4 fuera de 127 páginas

EFM CERTIFICATION EXAM 3 CERTIFICATION EVALUATION 2026 FULL QUESTIONS WITH SOLUTIONS

Vista previa del contenido

EFM CERTIFICATION EXAM 3 CERTIFICATION
EVALUATION 2026 FULL QUESTIONS WITH
SOLUTIONS

◉ How does the fetus compensate for decreased maternal
circulating volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement. Answer: b.
Increases cardiac output by increasing it's heart rate.


◉ Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
d. No change. Answer: a. A decrease in the heart rate


◉ What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels

,e. A & C
f. A & B
g. C & D. Answer: g. C & D


◉ The vagus nerve begins maturation 26 to 28 weeks. Its dominance
results in what effect to the FHR baseline?
a. Increases baseline
b. Decreases baseline. Answer: b. Decreases baseline


◉ T/F: Oxygen exchange in the placenta takes place in the
intervillous space.. Answer: True


◉ T/F: The parasympathetic nervous system is a cardioaccelerator..
Answer: False


◉ T/F: Baroreceptors are stretch receptors which respond to
increases or decreases in blood pressure.. Answer: True


◉ T/F: There are two electronic fetal monitoring methods of
obtaining the fetal heart rate: the ultrasound transducer and the
fetal spiral electrode.. Answer: True


◉ T/F: Variability can be determined with the fetoscope.. Answer:
False

,◉ T/F: Because the ultrasound transducer and toco transducer are
sealed units, they can be dipped in warm water to make cleaning
easier.. Answer: False


◉ T/F: The most common artifact with the ultrasound transducer
system for fetal heart rate is increased variability.. Answer: True


◉ T/F: All fetal monitors contain a logic system designed to reject
artifact.. Answer: True


◉ T/F: The monitor should always be tested before starting a
tracing, either external or internal mode and labeled a test.. Answer:
True


◉ T/F: The paper speed on the fetal monitor should always be set at
1cm/min.. Answer: False


◉ T/F: Both internal and external monitoring methods are equally
accurate means of obtaining the fetal heart rate and contraction
patterns.. Answer: False


◉ T/F: The external toco is usually placed over the uterine fundus to
pick up contractions.. Answer: True

, ◉ T/F: The external toco gives measurable uterine pressure..
Answer: False


◉ T/F: The fetal spiral electrode can be placed when vaginal
bleeding of unknown origin is present.. Answer: False


◉ T/F: The ultrasound transducer is usually placed on the side of
the uterus over the baby's back, as the fetal heart is heard best
there.. Answer: True


◉ T/F: The spiral electrode is used to more accurately determine the
frequency, duration, and intensity of uterine contractions.. Answer:
False


◉ T/F: The heart rate from a well-applied fetal spiral electrode can
only be fetal, not maternal.. Answer: False


◉ T/F: The intrauterine catheter is used to pick up the fetal heart
rate.. Answer: False


◉ T/F: The internal spiral electrode may pick up the maternal heart
rate if the baby has died.. Answer: True

Información del documento

Subido en
28 de febrero de 2026
Número de páginas
127
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
FocusFile7
4.0
(27)
Vendido
271
Seguidores
4
Artículos
72687
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes