• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 9 páginas
Examen

Computed Tomography- Test 4 || 100% Valid Solutions.

Document preview thumbnail
Vista previa 2 fuera de 9 páginas

Computed Tomography- Test 4 || 100% Valid Solutions.

Vista previa del contenido

Computed Tomography- Test 4 || 100% Valid Solutions.

Selectable Scan Factors correct answers 1. Scan Field of View
2. Display Field of View
3. Matrix Size
4. Slice Thickness
5. Reconstruction Algorithm
6. Scan Time & Rotation
7. Radiographic Tube Output
8. Region of Interest
9. Magnification
10. Focal Spot Size and Tube Geometry
11. Table Increment
12. Pitch

Scan Field of View (FOV) or.. Reconstruction Circle correct answers -is a circular region from
which the transmission measurements are recorded during scanning

-during data collection & image reconstruction, a matrix is placed over the scan FOV to cover
the slice to be imaged

-a technologist can select the FOV appropriate to the examination

Display Field of View (DFOV) correct answers -is the real dimensions of a view (width &
height) with reference to the RAS (right, anterior, superior) coordinates.

-the DFOV can be equal to or less than the scan FOV

Matrix Size correct answers -is the predetermined at 512 x 512 on current equipment

-matrix size is sometimes referred to as the FOV

-as the images become larger, they require more processing time and more storage space

Slice Thickness correct answers -should be adapted to the area of interest

-the number of millimeters (thickness) of anatomy penetrated by the x-ray beam

-determined by the collimation of the x-ray beam and partially determined by the focal spot

-affects anatomical coverage, image noise, resolution, and dose

-image noise is decreased with thicker slices

, -resolution is reduced with thicker slices (multiple tissues of different densities are superimposed
within the same slice and displayed as a single pixel)

-spatial resolution is better with thinner slices

********
-Routine Head: 2.5 to 5 mm slices
-C-Spine: 1 to 3 mm slices
-Lumbar: 3 to 5 mm slices

Reconstruction Algorithm correct answers -is a computer adapted mathematical calculation
applied to raw data during image reconstruction

-Basic Algorithm (used for brain, neck, and spine are):
*standard
*bone
*detail

-Standard Algorithm is chosen for most soft tissue imaging. Ex. brain and intervertebral discs
because it provides good spatial contrast

-Detail Algorithm is used for studying the soft tissues of the neck
*it increases edge definition of similar tissues

-Bone Algorithm is used to increase the sharpness of the bony detail
*optimizes spatial resolution; contrast resolution is poor

Scan Time and Rotation correct answers -refer to the duration of the scan

-the scan time depends on the patient's respiratory condition

-increasing the scan rotation time will result in better resolution because each image is generated
from more projections

-longer scan times can offer tube cooling but can increase pt motion

Radiographic Tube Output correct answers -AEC uses a technique referred to as Automatic Tube
Current Modulation (ATCM) to control the dose to the pt while maintaining constant image
quality regardless of pt size and tissue attenuation differences

-dose is directly proportional to the mA

-ATCM automatically controls the mA in 2 directions of the patient (x-y axis and z axis)

-Patient Coordinate System: Supine position
*z-axis extends along the patient table and the long axis of the patients body

Información del documento

Subido en
18 de febrero de 2026
Número de páginas
9
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.81

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SirAnton
3.7
(118)
Vendido
810
Seguidores
438
Artículos
40068
Última venta
1 día hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes