Double Check Valve Assembly - ANSWERA testable mechanical device consisting of two independently operating, spring-loaded check valves, four test cocks, and two full port shut off valves the purpose of an ASSE 1018 trap primer is to - ANSWERmaintain a trap seal a laboratory faucet vacuum breaker must contain - ANSWERtwo independently acting check valves

Vista previa del contenido

BACKFLOW EXAM QUESTIONS &
ANSWERS(GRADED A+)
Double Check Valve Assembly - ANSWERA testable mechanical device consisting of
two independently operating, spring-loaded check valves, four test cocks, and two full
port shut off valves

the purpose of an ASSE 1018 trap primer is to - ANSWERmaintain a trap seal

a laboratory faucet vacuum breaker must contain - ANSWERtwo independently acting
check valves

ASSE 1060 - ANSWERoutdoor enclosures standard, freeze protective enclosures must
provide protection to a remedies of -30 f

device - ANSWERa backflow prevents generally consisting of a single valve body not
capable of being field tested using a differential gauge

to stop a siphonic actin within a potable water system, we must - ANSWERadmit air into
the system

waterborne diseases - ANSWERtyphoid, cholera and giardiasis

a double check detector assembly installed on a antifreeze loop area requires -
ANSWERreplacement

removal of the relief valve spring on a reduced pressure principle assembly will cause
the assembly to - ANSWERbecome a approved double check valve assembly

when testing the first check valve in the direction of flow on a reduced pressure
assembly using a sight tube the tube must be a minimum of - ANSWER138.75

continuing discharge for a reduced pressure principle assembly during a no flow
condition may be caused by - ANSWERa debris fouling the number one check valve

negligence - ANSWERnot meeting ones responsibility and causing harm

residual pressure - ANSWERthe pressure available at a fixture or water outlet after
allowances are made for pressure

natural or propane fires domestic water heatersbare protected from excess pressure by
the installation of a.. - ANSWERthermal expansion tank

, installation of backflow assemblies results in - ANSWERdecrease in system water
pressure

according to the manufacturers instructions valve levers on a t&p relief valve should be
operated at least - ANSWERevery 12 months

the installation of backflow asswmblies result in - ANSWERvelocity spike

when installaing a thermal expanaion tank, you should always - ANSWERmatch the
tank air pressure to the syatem water pressure

what assembly creates a closed water system - ANSWERprz, double check valve
assembly, pressure reducing valve, dual check valve

relief valves according to manufacture instructions must be inspected - ANSWERevery
three months

temperture and pressure relief valves on domestic water equipment should be sized
based on - ANSWERbtu input, water volume

whats not allowed on a irrigation system - ANSWERdouble check

how do you calculate pressure at the bottom of 60 ft - ANSWER60÷.433

negative gauge pressure - ANSWERhigh usuage

test cock sizes - ANSWER1/4-3/4

a dual check - ANSWERdevice

backsiphon will be what psi - ANSWER0psi

negative pressure will result in - ANSWERhigh usage

more velocity= - ANSWERless pressure

barometric loop - ANSWER35ft high

non-testable - ANSWERdevice

install RP - ANSWER12in above the floor

assymbly - ANSWERare testable

swing connection - ANSWERillegal

Información del documento

Subido en
12 de febrero de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
shantelleG
4.0
(118)
Vendido
650
Seguidores
369
Artículos
18317
Última venta
2 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes