Design, material, and operational standards for DCVA & RPBA are found in the - ANSWERAWWA standards Approved backflow prevention assemblies must be designed to be - ANSWERdisassembled and repaired in line for all sizes

Vista previa del contenido

BACKFLOW TEST PREP 1
QUESTIONS & ANSWERS|| 2026
LATEST UPDATE!!!
Design, material, and operational standards for DCVA & RPBA are found in the -
ANSWERAWWA standards

Approved backflow prevention assemblies must be designed to be -
ANSWERdisassembled and repaired in line for all sizes

Check valves must be internally loaded and must be drip-tight - ANSWERin the
direction of flow with a minimum of 1 psi differential

The maximum allowable pressure loss through a 3/4" DCVA is - ANSWER10 psi

The maximum allowable pressure loss through a 3/4" RPBA is - ANSWER20 psi

The markings required to be on all approved backflow prevention assemblies include -
ANSWERmake, model, direction of flow, & MWP

As part of an inspection of the assembly a BAT must determine - ANSWERif the
assembly is currently listed and approved for the orientation that it is installed

A cross-connection is defined as any actual or potential physical connection between a
public potable water system or the consumer's potable water system and any source of
non-potable liquid, solid, or gas that could the potable water supply by backflow -
ANSWERcontaminate

The undesirable reversal of flow of water or other substances through a cross-
connection into the public water system or consumer's potable water system is -
ANSWERbackflow

Backsiphonage backflow is defined as backflow due to a reduction in system pressure.
What else must be present for - ANSWERan opening to atmosphere

Which of the following may cause backpressure backflow? - ANSWERany of the above
(elevated piping, pumps, hot water tanks)

A direct cross-connection is subject to - ANSWERboth backsiphonage and
backpressure

, An approved air gap is a physical separation between - ANSWERthe end of the potable
water supply pipe and the overflow rim of the receiving vessel, a distance of at least 2
times supply pipe diameter and never less than 1"

An approved air gap is acceptable as backflow protection for - ANSWERBackpressure
as well as Backsiphonage and both High and Low Health Hazard

An approved backflow prevention assembly is an RPBA, RPDA, DCVA, DCDA, PVBA,
or SVBA of make, model and size that is - ANSWERapproved by the Washington State
DOH, ODW

Newly installed backflow assemblies have a initial test primarily due to: high rate of
failure at the time of the - ANSWERdebris from within the supply piping

If a customer requires continuous water service it is recommended that - ANSWERa
parallel set of backflow assemblies appropriate for the degree of hazard be installed

The shut off valves used on approved Backflow Prevention assemblies must always be
- ANSWERresilient seated

An approved backflow prevention assembly must be installed in such a manner that -
ANSWERit will not become flooded and with adequate space around the assembly to
facilitate testing and maintenance

An RPBA must not be installed where - ANSWERall of the above (water spilt from the
assembly will be objectionable, the assembly will become flooded, the assembly is more
than 60 inches above the floor or ground)

A "special application device" is a term used to describe mechanical backflow
preventers that - ANSWERdo not meet the design requirements of an approved
backflow prevention assembly

In a backsiphonage event, if an approved SVBA is installed properly - ANSWERthe
check valve will close tight to make a water tight seal and the air inlet valve will fully
open

A differential pressure test kit is used to measure - ANSWERthe difference between
high and low pressure in an approved backflow prevention assembly

A compensating valve may be used to - ANSWERcompensate for a leaking SOV #1
while testing an approved DCVA

A sight tube is used while testing an approved - ANSWERDCVA

Información del documento

Subido en
12 de febrero de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
shantelleG
4.0
(118)
Vendido
650
Seguidores
369
Artículos
18317
Última venta
2 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes