Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

BACKFLOW PREVENTION PRACTICE EXAM CORRECT 100%

Puntuación
-
Vendido
-
Páginas
18
Grado
A+
Subido en
12-02-2026
Escrito en
2025/2026

Containing a plumbing system from the public water supply requires backflow protection at the _______? A. Appliance or fixture B. Building foundation C. Irrigation system D. Service Connection E. Sprinkler riser - ANSWERService Connection Backflow preventer manufacturers recommend that assemblies be field-tested annually and when_____? A. Installed B. Moved C. Repaired or Installed D. Shut down E. Water suppliers provide notice - ANSWERRepaired

Mostrar más Leer menos
Institución
Backflow Certification
Grado
Backflow certification

Vista previa del contenido

BACKFLOW PREVENTION PRACTICE
EXAM CORRECT 100%
Containing a plumbing system from the public water supply requires backflow protection
at the _______?
A. Appliance or fixture
B. Building foundation
C. Irrigation system
D. Service Connection
E. Sprinkler riser - ANSWERService Connection

Backflow preventer manufacturers recommend that assemblies be field-tested annually
and when_____?
A. Installed
B. Moved
C. Repaired or Installed
D. Shut down
E. Water suppliers provide notice - ANSWERRepaired or Installed

A differential pressure gauge reading of 0.2 psid is represented on water column sight
tube by _____?
A. 1/16 in. (0.16 cm)
B. 1/2 in. (1.3 cm)
C. 2 in. (5.1 cm)
D. 3.5 in. (8.9 cm)
E. 5.5 in. (14 cm) - ANSWER5.5 in. (14 cm)

Pollution of a public water supply suggests the substance in the water is ____?
A. Aesthetically bad
B. Biological with virus only
C. Lowering the pH below 1.4
D. Radiological
E. Toxic - ANSWERAesthetically bad

Backsiphonage may occur when the pressure inside copper tubing is ____?
A. Greater than atmospheric pressure
B. Greater than barometric pressure
C. Greater than 0 gauge pressure
D. Less than absolute pressure
E. Less than atmospheric pressure - ANSWERLess than atmospheric pressure

A cross-connection may be a permanent piping arrangement or a(n) ____?
A. Backflow preventer
B. Church symbol

,C. OSHA hazardous area designation
D. Railroad and highway intersection sign
E. Temporary hose bibb connection - ANSWERTemporary hose bibb connection

The isolation of a plumbing water system hazard requires____?
A. Appliance protection
B. Building quarantine
C. High-hazard protection
D. Meter protection
E. Toxin monitoring - ANSWERAppliance protection

A direct cross-connection suggests the piping system may be subjected to ____?
A. Backpressure or backsiphonage
B. Backsiphonage only
C. Periodic inspection
D. Sustained pressure
E. Toxic materials - ANSWERBackpressure or backsiphonage

A pipe restriction's flow velocity increase may allow ____?
A. Aspiration
B. Backpressure
C. Low turbulence
D. Pressure head
E. Pressure surges - ANSWERAspiration

Water supply contamination from backflow may result in ____?
A. A bad taste
B. Coloration
C. Death
D. Odor or smell
E. Pipe wall mineral deposit flaking - ANSWERDeath

To prevent backflow, an atmospheric vacuum breaker is primarily designed to ____?
A. Allow air into the outlet piping system
B. Create an elevation loop above ground
C. Introduce head loss
D. Prevent backpressure
E. Restrict velocity - ANSWERAllow air into the outlet piping system

Atmospheric vacuum breakers will typically be located on ____?
A. Commercial irrigation systems
B. Fire-suppression systems
C. Plumbing fixtures or appliances
D. Utility storage tanks
E. Water service connections - ANSWERPlumbing fixtures or appliances

, The mechanical component of an atmospheric vacuum breaker serves as an air-inlet
valve and a ____?
A. Check valve
B. Regulating valve
C. Relief valve
D. Shut-off valve
E. Test port - ANSWERCheck valve

A deck-mounted atmospheric vacuum breaker's critical installation level is above the
outlet usage by ___?
A. 1 in. (2.5 cm)
B. 3 in. (7.6 cm)
C. 6 in. (15 cm)
D. 12 in. (30 cm)
E. 18 in. (46 cm) - ANSWER1 in. (2.5 cm)

A hose-bibb connection is required to have a permanently installed ____?
A. Atmospheric vacuum breaker
B. Backflow preventer
C. Pressure vacuum breaker
D. Shut-off valve
E. Spill-resistant vacuum breaker - ANSWERAtmospheric vacuum breaker

Atmospheric vacuum breakers must not be subject to continuous water pressure for
more than ___ hr.
A. 3
B. 6
C. 12
D. 18
E. 24 - ANSWER12

A submerged atmospheric vacuum breaker may be considered a(n) _____?
A. Backflow preventer
B. Cross-connection
C. Expensive elbow
D. Typical installation
E. Useful training photo - ANSWER. Cross-connection

Flow from the outlet of an atmospheric vacuum breaker must not reach a _____?
A. Closed tank
B. Section of straight tubing
C. Submerged inlet
D. Toxic substance
E. Valve - ANSWERValve

An atmospheric vacuum breaker is not required to have a(n) _____?

Escuela, estudio y materia

Institución
Backflow certification
Grado
Backflow certification

Información del documento

Subido en
12 de febrero de 2026
Número de páginas
18
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$16.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
shantelleG West Virgina University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
625
Miembro desde
3 año
Número de seguidores
369
Documentos
18116
Última venta
2 semanas hace
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.0

118 reseñas

5
69
4
11
3
24
2
2
1
12

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes