1) Backflow is the undesirable reversal of flow of water or other substances through a cross connection into the public water system or consumer's: - ANSWERC. Public water system or consumer's portable water system 2) An approved airgap (AG) is a physical separation between the free-flowing end of a: - ANSWERD. Potable water supply pipe line in the overflow rim of an open or non-pressurized receiving vessel 3) And indirect cross-connection is one that is subject

Vista previa del contenido

BACKFLOW PRACTICE EXAM
QUESTIONS & SOLUTIONS(RATED
A+)
1) Backflow is the undesirable reversal of flow of water or other substances through a
cross connection into the public water system or consumer's: - ANSWERC. Public water
system or consumer's portable water system

2) An approved airgap (AG) is a physical separation between the free-flowing end of a: -
ANSWERD. Potable water supply pipe line in the overflow rim of an open or non-
pressurized receiving vessel

3) And indirect cross-connection is one that is subject to what type of backflow? -
ANSWERA. Only backsiphonage

4 )Cross-connections with between the portable water piping in any piping or containers
containing substances not approved as potable water must be either eliminated or
controlled by the installation of an: - ANSWERD. Approved air gap or an approved
backflow prevention assembly

5) While testing CV #2 of a DCVA if CV #2 leaks the BAT would observe that the water
flow: - ANSWERD. Stops from the site tube at TC#4 and no differential shows on the
gauge

6) Service protection is a way to protect a public water system from contamination due
to back flow from the customer's water system by the installing an approved backflow
preventer at the: - ANSWERA. Service connection which is considered to be at or near
the water meter

7) A Washington state certified Backflow Assembly Tester is certified to: - ANSWERD.
Inspect, test and monitor backflow prevention assemblies

8) The RPBA is designed so that if the check valve leaks, the relief with valve may: -
ANSWERB. Open to discharge through the relief valve vent

9) An AG installed in lieu of an approved backflow prevention assembly must be
inspected for compliance with the definition of an improved air gap by: - ANSWERC.
Either a CCS or a BAT

10) After testing an approved backflow prevention assembly the BAT shall complete a
test report that is acceptable to the: - ANSWERC. Purveyor

11) The gauge on a differential pressure test kit indicates: - ANSWERC. psid

, 12) Loading a check valve with springs or weights: - ANSWERC. Reduces pressure
down stream of the check valve

13) If there is flow across CV#1 and through an RPBA the relief valve will not discharge
unless: - ANSWERC. The relief valve is defective

14) Microbiological contaminates entering the portible water system are always a: -
ANSWERA. High-health standard

15) All approved backflow prevention assemblies must be tested with a: - ANSWERD.
Differential pressure test kit

16) An approved backflow prevention assembly is an: - ANSWERC. RPBA, RPDA,
DCVA, DCDA, PVBA, or SVBA of make, model, and size that is approved by the DOH

17) Permanent support blocks are required under all approved backflow assemblies that
are: - ANSWERD. A large size assembly

18) A backflow assembly test report must be: - ANSWERC. Complete, accurate and
legible

19) SOV #1 of a properly installed PVBA
is reported as leaking while testing the air inlet valve if water continues to flow from: -
ANSWERC. The high-bleed valve and the differential gauge does not drop to the
opening point of the Air Inlet Valve

20) The differential pressure relief valve must discharge water to the atmosphere when
the pressure in the zone between the check valves is with in: - ANSWERB. 2 psi of the
pressure upstream of CV #1

21) The Undesirable reversal of flow of water or other substances through a cross
connection into the public water system or consumers potible water system is: -
ANSWERD. Backflow

22) While testing CV#2 of an RPBA the BAT must determine if CV#2 closes tight: -
ANSWERD. In the reverse direction of flow

23) A DCDA should not be installed: - ANSWERB. Where pressure in the water system
is greater than the assembly's maximum working water pressure

24) The contents of the backflow assembly test report completed after testing a
backflow prevention assembly installed at the water meter must meet the requirements
of the: - ANSWERD. Water purveyor

Información del documento

Subido en
12 de febrero de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
shantelleG
4.0
(118)
Vendido
650
Seguidores
369
Artículos
18317
Última venta
2 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes