ETA LEJATC YEAR 1 QUIZ 4 REVIEW QUESTIONS ANSWERED CORRECTLY LATEST UPDATE 2026 A(n) ? box is installed at an endpoint in an electrical system where current is supplied to utilization equipment. e t ty - Answers B ? is a non-threadable conduit that is rustproof and commonly available in Schedule 40 and Schedule 80 wall thicknesses. a.Electrical metallic tubing b.Intermediate metal conduit c.PVC conduit d.Rigid metal conduit - Answers C A(n) ? box is also called a "J-box." ion ty - Answers B ? provides an excellent ground path and it can be bent with virtually no springback. a.Aluminum conduit b.Electrical metallic tubing c.PVC-coated rigid metal conduit d.Rigid nonmetallic conduit - Answers A Identify the type of connector shown below. a.90° elbow b.90° pulling elbow c.Hub d.Set screw ***IT SHOWS A 90 DEGREE ELBOW*** - Answers A ? is a threadable conduit that has a rubberized outside coating and is commonly installed in highly corrosive environments. a.Electrical metallic tubing b.Intermediate metal conduit c.Liquidtight flexible metal conduit d.PVC-coated rigid metal conduit - Answers D ? is a threadable conduit with an intermediate wall thickness compared to rigid metal conduit. a.Electrical metallic tubing b.Intermediate metal conduit c.PVC conduit d.Rigid nonmetallic conduit - Answers B Identify the type of conduit body shown below. a.LB b.LL c.LR d.T - Answers C Identify the type of conduit body shown below. a.LB b.LL c.LR d.T - Answers A A(n) ? box typically houses switches and receptacles. e t ty - Answers A Threads for conduit fittings are straight without a taper. Select one: True False - Answers True Cutting with ? is a messy process because large amounts of debris from the conduit and blade are left behind. ive saws saws aws et cutters - Answers A Threading machines are available to thread conduit from ? . a.½" to 2" b.½" to 4" c.¾" to 2" d.¾" to 6" - Answers B A(n) ? consists of a handle, grip, and head that remove the sharp edges on conduit. bucket r der - Answers C A ? is also called a "diestock." head ratchet r - Answers B A ? is a handheld power saw that has a flexible metal saw blade forming a continuous loop around two parallel pulleys. saw aw c.PVC saw et cutter - Answers A The handles of a ? are opened and closed several times to provide a mechanical advantage, which can easily cut through thick-walled pipes. saw aw c.PVC saw et cutter - Answers D ? threads are used on conduit. a.British Standard Pipe (BSP) b.National Pipe Taper (NPT) c.National Pipe Taper Thread Fuel (NPTF) d.Special Unified National Thread Series (UNS) - Answers B A ? is a conduit threader in which the die head is secured to the threader in a fixed position. -ratcheting hand-driven threader pony eting hand-driven threader ding machine - Answers A A ? is a manual saw that is designed to hold various types of blades for cutting different materials. saw cutting saw aw et cutter - Answers C A(n) ? is a cutting tool used to form external threads on the surface of conduit. saw r - Answers B The teeth on a ? are designed to efficiently cut plastic conduit with minimal heat build-up. saw aw c.PVC saw et cutter - Answers C There should be no less than ? threads worth of contact between the conduit and fitting. a.3 b.5 c.7 d.10 - Answers B ? are manually-operated threading tools that require the arm strength of the Electrical Worker to turn the die around the conduit. a.Hand-driven threaders b.Mechanical threaders c.Power-driven threaders d.Threading machines - Answers A If the actual stub length is less than the desired stub length (due to bender wear), the difference between the two stub lengths is ? . to the take-up garded plied by 2 acted from the take-up - Answers D Determine the overall length (OAL) of a ¾-inch EMT conduit with a total of two 90° bends. The finished dimensions of the conduit are 66.6 inches back-to-back (B2B) with the first stub length (Stub 1) of 21.9 inches and the second stub length (Stub 2) of 14.2 inches. The gain for your bender is 3.32 inches. (Round your FINAL answer to the nearest tenth or one decimal place.) - Answers OAL = (Stub 1 - Bender Gain) + B2B + (Stub 2 - Bender Gain) = (21.9 - 3.32) + 66.6 + (14.2 - 3.32) = 96.06 ≈ 96.1 inches The ? must always be the primary source of force used to bend conduit. pedal e y - Answers A It can be assumed that the take-up value is the same for all benders of the same size. Select one: True False - Answers False In order to place the bending mark in the correct position on the conduit, the take-up must first be subtracted from the ? . -to-back distance it length length - Answers D Determine the proper distance (D) of a pencil mark from the end of a piece of 1-inch EMT when the desired stub-up (Stub 1) length of a 90° bend is 33 inches. - Answers Distance (D) = Stub - Bender Take Up = 33 - 8 = 25 inches Determine the proper distance (D) of a pencil mark from the end of a piece of ¾-inch EMT when the desired stub-up (Stub 1) length of a 90° bend is 30 inches. - Answers Distance (D) = Stub - Bender Take Up = 30 - 6 = 24 inches Benders are manufactured to create a specific ? . angle type t s - Answers D Determine the proper distance (D) of a pencil mark from the end of a piece of ½-inch EMT when the desired stub-up (Stub 1) length of a 90° bend is 23 inches. - Answers Distance (D) = Stub - Bender Take Up = 23 - 5 = 18 inches Determine the overall length (OAL) of a 1-inch EMT conduit with a total of two 90° bends. The finished dimensions of the conduit are 61.4 inches back-to-back (B2B) with the first stub length (Stub 1) of 13.0 inches and the second stub length (Stub 2) of 21.5 inches. The gain for your bender is 4.02 inches. (Round your FINAL answer to the nearest tenth or one decimal place.) - Answers OAL = (Stub 1 - Bender Gain) + B2B + (Stub 2 - Bender Gain) = (13.0 - 4.02) + 61.4 + (21.5 - 4.02) = 87.86 ≈ 87.9 inches Determine the overall length (OAL) of a 1-inch EMT conduit with a total of two 90° bends. The finished dimensions of the conduit are 51.9 inches back-to-back (B2B) with the first stub length (Stub 1) of 14.8 inches and the second stub length (Stub 2) of 12.4 inches. The gain for your bender is 3.89 inches. (Round your FINAL answer to the nearest tenth or one decimal place.) - Answers OAL = (Stub 1 - Bender Gain) + B2B + (Stub 2 - Bender Gain) = (14.8 - 3.89) + 51.9 + (12.4 - 3.89) = 71.32 ≈ 71.3 inches The ? mark indicates the position of the conduit where the bend will begin to be formed. - Answers B All hand benders include a hook, ? , handle, and foot pedal. e - Answers D

Vista previa del contenido

ETA LEJATC YEAR 1 QUIZ 4 REVIEW QUESTIONS ANSWERED CORRECTLY LATEST UPDATE 2026

A(n) ? box is installed at an endpoint in an electrical system where current is supplied to utilization
equipment.
a.device
b.outlet
c.pull
d.utility - Answers B
? is a non-threadable conduit that is rustproof and commonly available in Schedule 40 and Schedule
80 wall thicknesses.
a.Electrical metallic tubing
b.Intermediate metal conduit
c.PVC conduit
d.Rigid metal conduit - Answers C
A(n) ? box is also called a "J-box."
a.joist
b.junction
c.pull
d.utility - Answers B
? provides an excellent ground path and it can be bent with virtually no springback.
a.Aluminum conduit
b.Electrical metallic tubing
c.PVC-coated rigid metal conduit
d.Rigid nonmetallic conduit - Answers A
Identify the type of connector shown below.
a.90° elbow
b.90° pulling elbow
c.Hub
d.Set screw

***IT SHOWS A 90 DEGREE ELBOW*** - Answers A
? is a threadable conduit that has a rubberized outside coating and is commonly installed in highly
corrosive environments.
a.Electrical metallic tubing
b.Intermediate metal conduit
c.Liquidtight flexible metal conduit
d.PVC-coated rigid metal conduit - Answers D
? is a threadable conduit with an intermediate wall thickness compared to rigid metal conduit.
a.Electrical metallic tubing
b.Intermediate metal conduit
c.PVC conduit
d.Rigid nonmetallic conduit - Answers B
Identify the type of conduit body shown below.
a.LB
b.LL
c.LR
d.T - Answers C
Identify the type of conduit body shown below.
a.LB
b.LL
c.LR
d.T - Answers A
A(n) ? box typically houses switches and receptacles.
a.device
b.outlet
c.pull
d.utility - Answers A

, Threads for conduit fittings are straight without a taper.
Select one:
True
False - Answers True
Cutting with ? is a messy process because large amounts of debris from the conduit and blade are left
behind.
a.abrasive saws
b.band saws
c.hacksaws
d.ratchet cutters - Answers A
Threading machines are available to thread conduit from ? .
a.½" to 2"
b.½" to 4"
c.¾" to 2"
d.¾" to 6" - Answers B
A(n) ? consists of a handle, grip, and head that remove the sharp edges on conduit.
a.oil bucket
b.oiler
c.reamer
d.threader - Answers C
A ? is also called a "diestock."
a.die
b.die head
c.hand ratchet
d.reamer - Answers B
A ? is a handheld power saw that has a flexible metal saw blade forming a continuous loop around
two parallel pulleys.
a.band saw
b.hacksaw
c.PVC saw
d.ratchet cutter - Answers A
The handles of a ? are opened and closed several times to provide a mechanical advantage, which can
easily cut through thick-walled pipes.
a.band saw
b.hacksaw
c.PVC saw
d.ratchet cutter - Answers D
? threads are used on conduit.
a.British Standard Pipe (BSP)
b.National Pipe Taper (NPT)
c.National Pipe Taper Thread Fuel (NPTF)
d.Special Unified National Thread Series (UNS) - Answers B
A ? is a conduit threader in which the die head is secured to the threader in a fixed position.
a.non-ratcheting hand-driven threader
b.power pony
c.ratcheting hand-driven threader
d.threading machine - Answers A
A ? is a manual saw that is designed to hold various types of blades for cutting different materials.
a.band saw
b.dry cutting saw
c.hacksaw
d.ratchet cutter - Answers C
A(n) ? is a cutting tool used to form external threads on the surface of conduit.
a.band saw
b.die
c.oiler
d.reamer - Answers B

Información del documento

Subido en
7 de febrero de 2026
Número de páginas
9
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
joshuawesonga22
3.4
(12)
Vendido
114
Seguidores
2
Artículos
15049
Última venta
3 semanas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes