• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 53 páginas
Examen

HVAC Journeyman’s Study Set – Complete Practice Questions & Study Guide

Document preview thumbnail
Vista previa 4 fuera de 53 páginas

Prepare for the HVAC Journeyman certification with this comprehensive study set. Covers system operation, refrigeration cycles, troubleshooting techniques, maintenance procedures, and safety protocols. Includes practice questions with detailed explanations to reinforce understanding, support exam preparation, and build confidence for successful certification. Designed for trainees, students, and professionals seeking structured study resources.

Vista previa del contenido

HVAC Journeyman's Study Set Question and Answers.pdf/
HVAC Journeyman's
2026 with Solution
Study Set Question and Answers
HVAC Journeyman's Study Set Question and Answers.pdf




HVAC Journeyman's Study Set Question
and Answers


The maximum horizontal length of a single-wall connector shall be ____ percent of the height
of the chimney or vent.
75%




Grease filters shall be installed at an angle of not less that ____ degrees from the horizontal and
shall be equipped with a drip tray beneath the lower edge of the filters
45




A device that will automatically shut off the fuel supply to a main burner or group of burners
when the means of ignition of such burners become inoperative, and when flame failure occurs
on the burner or group of burners.
Flame Safeguard




Fire dampers shall not be installed in.
Exhaust ducts.




Metallic ducts not having an approved protective coating shall be completely encased in a
minimum of ___ inches of concrete
2 inches




HVAC Journeyman's Study Set Question and Answers.pdf
HVAC Journeyman's StudyHVAC
Set Question
Journeyman's
and Answers
Study Set Question and Answers.pdf/ 2026 with Solution

,HVAC Journeyman's Study Set Question and Answers.pdf/
HVAC Journeyman's
2026 with Solution
Study Set Question and Answers
HVAC Journeyman's Study Set Question and Answers.pdf




An appliance that operates with a nonpositive vent static pressure and with a vent gas
temperature that is capable of causing excessive condensate production in the vent.
Category 2




Type L shall terminate not less than two feet above the highest point of the roof penetration
and not less than ______ feet higher than any portion of a building
2 Feet




Duct Linings shall be interrupted at the area of operation of a fire damper in at a minimum of 6
inches _____ of and 6 inches downstream of electric resistance and fuel burning heaters in a
duct system
Upstream




A container that is placed at a low point in a system of piping to collect condensate and from
which the condensate is removable.
Drip leg




Infrared radiant heaters shall be _____ in a position independent of fuel and electric supply
lines hangers and bracket shall be non-combustible material
Fixed




HVAC Journeyman's Study Set Question and Answers.pdf
HVAC Journeyman's StudyHVAC
Set Question
Journeyman's
and Answers
Study Set Question and Answers.pdf/ 2026 with Solution

,HVAC Journeyman's Study Set Question and Answers.pdf/
HVAC Journeyman's
2026 with Solution
Study Set Question and Answers
HVAC Journeyman's Study Set Question and Answers.pdf




In the absence of MFG information openings covered with metal louvers shall be deemed to
have a net free area of 75% of the area of the opening, and openings covered with ____ louvers
shall be deemed to have a net free area of 25% of the area of the opening.
Wood




Opening sizes in Louver, grilles, and screens protecting outdoor exhaust and air intake openings
you would use which table?
Table 401.5




A hole not greater in diameter than ____ % of the stud depth is permitted to be bored in any
wood stud.
40%




Reclaimed refrigerants and used refrigerants shall not be reused in a different owner's
equipment or appliances. Unless test and meets purity requirements of _____.
ARI 700




where multiple air-handling systems share common supply or return air ducts or plenums with
a combined design capacity greater than 2000 cfm, the return air systen shall be provided with.
Smoke detector




The length of overlap for overlapping duct joints shall not exceed ___ inches.
2 inches




HVAC Journeyman's Study Set Question and Answers.pdf
HVAC Journeyman's StudyHVAC
Set Question
Journeyman's
and Answers
Study Set Question and Answers.pdf/ 2026 with Solution

, HVAC Journeyman's Study Set Question and Answers.pdf/
HVAC Journeyman's
2026 with Solution
Study Set Question and Answers
HVAC Journeyman's Study Set Question and Answers.pdf




A yellow insulated copper Tracer wire or other approved conductor shall be installed adjacent
to underground non-metallic piping access shall be provided to the Tracer wire or the Tracer
wire shall terminate above ground at each end of the nonmetallic piping the Tracer wire shall
not be less than _____ AWG and the insulation type shall be suitable for the direct burial
18 AWG




Excavations are ___ feet in depth and examination of the ground shows no indication of
potential cave in.
5 feet




An appliance that operates with a nonpositive vent static pressure and with a vent gas
temperature that avoids excessive condensate production in the vent.
Category 1




A safety valve designed to forestall the development of a dangerous condition by relieving
either pressure, temperature. or vacuum in hot water supply system.
Relief Valve




All refrigerant containing parts and systems exceeding 100 horsepower Drive power except
evaporators used for refrigeration or dehumidification; condensers used for heating control and
pressure valves for either; and connecting piping, shall be located either.
Outdoors or in a machinery room.




Connector length. Flexible air connectors shall be limited in length to _____ feet.




HVAC Journeyman's Study Set Question and Answers.pdf
HVAC Journeyman's StudyHVAC
Set Question
Journeyman's
and Answers
Study Set Question and Answers.pdf/ 2026 with Solution

Información del documento

Subido en
22 de enero de 2026
Número de páginas
53
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$21.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
UniTest
4.8
(219)
Vendido
8291
Seguidores
16
Artículos
1111
Última venta
2 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes