Terms in this set (602)
= 0.0505 X GPM X √NP Fog Nozzle Reaction
1.57 X d² X NP Smooth Bore Nozzle Reaction
2 In order for a fire apparatus to be classified as a "quint". It
must carry a minimum of ___________ combination spray nozzles
capable of flowing 95 GPM (360 L/Min)
3/4 = 1100 2 1/2 = 2 Friction Coefficients
1 = 150 3 with 2 1/2 couplings = 0.8
1 1/2 = 24 3 with 3 couplings = 0.67
1 3/4 = 15.5 3 1/2 = .34
2= 8 4 = .2
4 1/2 =.1
5= .08
6= .05
,15 ft (4.5 m); 20 ft (6m) If a mobile water supply apparatus is equipped with a fire
pump, it must carry a minimum of ___________ of soft suction
hose _____________ of hard suction hose with a strainer.
29.7 X d² X √NP Formula for GPM
35 mi/h According to NFPA 1901, all fire service apparatus must,
when loaded to its estimated in service weight, be capable o
attaining a minimum speed of ______________ within 25 seconds
from a standing start while on dry, paved roads that are in
good condition.
85 ft (26-m) NFPA 1901 states that the quint shall be equipped with a
minimum total complement of _____________ of ground ladders.
115 Ft (35 M) According to NFPA 1901, for a fire apparatus to meet the
classification of aerial, what is the minimum number of feet in
length that the total complement of ground ladders must
meet?
115 ft (35 m) To be considered an aerial fire apparatus as defined by
NFPA 1901, the apparatus must include at a minimum, a
_____________ total complement of ground ladders that are
supplied and installed by the manufacturer.
,200:1 to 1000:1 High-expansion foam has a foam expansion ratio in the
range of:
200 gallons (750 L According to NFPA 1901, in order for a fire apparatus to be
classified as an initial attack fire apparatus, it must have a
water tank capable of carrying a minimum of:
250 (1000 L/Min) According to NFPA 1901, in order for a fire apparatus to be
classified as an initial attack fire apparatus, it must have a
pump rated a minimum of ___________ GPM.
300 FT (90 m); 2 1/2- inch (65-mm) To be classified as an initial attack pumper, NFPA 1901
requires a minimum of ________________ of ___________________ or larger
fire supply hose.
300 Gallons ( 1135 L) An apparatus must carry a minimum of _______________ of water to
be classified as a pumper.
A 360-degree inspection refers to a(n): Complete walk- around inspection of the unit before you go
on a response
400 Ft (120 m) According to NFPA 1901, what is the minimum amount of
attack hose to be carried on a pumper?
, 400 ft (120 m) According to NFPA 1901, what is the minimum amount of
attack hose to be carried on an initial attack fire apparatus?
A 500-ft lay of 5-inch hose can supply: 700 gpm
750 gallons (2840 L) According to NFPA 1901, a pumper should be equipped with
permanently mounted pump at a minimum rating of __________
of water per minute.
750 gpm (3000 L/min) The mobile foam fire apparatus, as defined in NFPA 1901,
shall be equipped with a fire pump that has a minimum rated
capacity of:
800 ft (240 m) According to NFPA 1901, what is the minimum amount of
supply hose to be carried on a pumper?
1000 gallons (4000 L) In order for a fire apparatus to be classified as a mobile
water supply apparatus, it must have a water tank that holds a
minimum of:
1000 gallons (4000 L) A mobile water supply apparatus is equipped with one or
more water tanks that meet the requirements of NFPA 1901
and have a minimum certified capacity of: