NCCER • NCCER
Latest uploads for NCCER at NCCER. Looking for NCCER notes at NCCER? We have lots of notes, study guides and revision notes available for NCCER at NCCER.
-
33
- 0
-
3
Modules NCCER at NCCER
Notes available for the following courses of NCCER at NCCER
Latest content NCCER • NCCER
NCCER Construction Safety, Tools and 
Machinery| Exam Finals 2025| Midterm 
Questions and Answers 
What could happen if a worker ignores a “spotter” while operating a forklift near other workers? 
They might hit someone or damage materials. The spotter’s there for a reason—to help guide 
safely, especially where vision is blocked. 
On a site where power tools are being used, what’s the biggest risk if cords are running across 
walkways? 
People could trip and fall, or equipment...
NCCER Concrete Construction| 
Certification Exam 2025| Questions and 
Answers (Multiple Choice) 
Which tool is best for striking off excess concrete to level it with the top of the form? 
A) Trowel 
B) Bull float 
C) Screed 
D) Edger 
C) Screed 
Because a screed is long and straight, it’s used to level freshly placed concrete by dragging it 
across the top surface. A bull float smooths, but doesn’t level. 
Freshly placed concrete should be compacted mainly to: 
A) Make it dry fas...
NCCER Concrete Construction |Review 
Question and Answers| Fully Updated 
Paper 2025 
A slab is being poured on a super hot day, and the surface is drying way too fast. What’s a good 
reason that’s a problem? 
If the surface dries faster than the rest of the slab, it can lead to cracking because the concrete 
shrinks unevenly. That messes with its strength and looks bad too. 
A worker installs a 90° elbow but forgets to clean the pipe ends. What issue could that cause later 
on? 
N...
NCCER Basic Safety Guides and 
Protocols| certification Questions and 
Answers| 100% 2025 Update 
What should a worker do immediately after noticing a frayed extension cord on a construction 
site? 
Tag it out so nobody uses it, then report it right away. You don’t fix it yourself—just make 
sure it can’t be used until someone qualified checks it. 
When using a ladder near an entry door, what safety step should be taken first? 
Block off the door or post a warning sign so no one ac...
Module 7 NCCER Basic Communication 
Skill Test| Questions and Answers| 
Updated 2025 
You’re on a job site and a coworker gives you instructions, but there’s loud machinery in the 
background. What’s a good move to make sure you understood them? 
Ask them to repeat it or move somewhere quieter to confirm what they said. Better to 
double-check than mess something up ‘cause you misheard. 
Someone sends you an email with unclear instructions. What should you do before starting the ...
Module 2 NCCER| Introduction to 
Construction| Math Test| Exam 
Questions and Answers| Updated 2025 
A carpenter cuts a 12 ft board into 3 equal pieces. Which measurement shows the length of one 
piece? 
4 ft — Dividing 12 ft by 3 gives you 4 ft per piece. Simple division, just like breaking up a 
pizza. 
A plumber reads a tape measure showing 3 full inches and 3 small lines after it. If each line is 
1/16 inch, what’s the measurement? 
3 3/16 inches — The small lines after the in...
Level 1 and 2 NCCER |Electrical Module 5 
(NEC) Quizzes| VERIFIED| 2025/2026 
Certification 
What happens if a junction box doesn’t have enough space for all the wires and devices inside? 
It can lead to overheating or short circuits because the wires are crammed and can’t dissipate 
heat properly. NEC has box fill rules for a reason—too many wires in a tight space is asking for 
trouble. 
When a 14 AWG conductor is protected by a 30A breaker, what NEC rule is being broken? 
You’...
Electrician NCCER| Final Review 
Assessment Level 2| Questions and 
Verified Solutions 2025 
What’s the risk if a neutral wire in a 120/240V system is loose at the panel? 
It can cause voltage imbalance—like some outlets showing way more than 120V and others 
less. Worst case, it fries connected devices. 
A journeyman tells you to torque all terminations per spec—why’s that a big deal? 
Loose or overtightened connections can overheat or fail. Spec torque makes sure everything's...
Core Curriculum NCCER| (6th Edition)| 
Final Review 2025| Complete Questions 
and Answers 
A worker sees a frayed extension cord being used with a power tool on a job site. What should 
happen next? 
Stop using it right away and tag it out or report it. Frayed cords are a fire and shock risk, and 
using damaged equipment is a huge safety violation. 
A team is lifting materials with a crane and one worker is giving hand signals. Why is only one 
signal person used? 
To avoid confusion. E...