QUESTIONS WITH VERIFIED ANSWERS
◉ A group I-1 occupancy shall include a building or part thereof for
more than ____ persons who reside on a 24-hour basis in a supervised
environment and receive custodial care? Answer: 16
◉ Semiconductor fabrication facilities and comparable research and
development areas in which hazardous production materials (HPM) are
used are classified as Group ____. Answer: H-5
◉ Buildings and structures that contain materials that are health hazards
shall be classified as Group ____ where the amounts exceed the
maximum allowable quantities? Answer: H-4
◉ Buildings or structures that contain materials that readily support
combustion or present a physical hazard shall be classified as Group
____. Answer: H-3
◉ Buildings and structures that contain materials that present a
deflagration hazard or a hazard from accelerated burning shall be
classified as Group ____. Answer: H-2
,◉ A Group I-1 assisted living facility where the care recipients may
require limited verbal or physical assistance during egress activities is
considered condition ____. Answer: 2
◉ Hospitals, nursing homes and similar medical care facilities shall be
classified as Group _____ occupancies? Answer: I-2
◉ Nursing homes are considered to be Group I-2, Condition ____
occupancies? Answer: 1
◉ A Group I-3 occupancy shall include buildings that are inhabited by
more than ____ persons who are under restraint or security? Answer:
five (5)
◉ Rooms and spaces within places of religious worship providing
custodial care during religious functions shall be classified as ____ ,
____ , ____ , ____ , ____ ? Answer: part of the primary occupancy
◉ Motor fuel-dispensing facilities and department stores are examples
of Group ____ occupancies? Answer: M
◉ Owner occupied lodging houses with ____ or fewer guest rooms and
____ or fewer total occupants are permitted to be constructed in
accordance with the International Residential Code? Answer: five (5),
ten (10)
,◉ Transient hotels and motels are examples of Group ____
occupancies? Answer: R-1
◉ A room used for storage purposes that is ____ to another occupancy
shall be classified as part of that occupancy? Answer: accessory
◉ Apartment houses are considered Group ____ occupancies? Answer:
R-2
◉ Facilities for more than five but not more than 16 occupants,
excluding staff, who reside on a 24-hour basis in a residential
environment and receive custodial care are Group ____ occupancies?
Answer: R-4
◉ Nontransient congregate living facilities with ____ or fewer
occupants are classified as Group R-3 occupancies? Answer: 16
◉ Buildings used for storage that are not classified as a hazardous
occupancy are classified as Group ____? Answer: S
◉ Barns, private garages, tanks, and towers are all examples of Group
_____ occupances? Answer: U
, ◉ In a covered mall building, a fire-resistance-rated separation is not
required between _________ and the mall? Answer: tenant spaces
◉ In determining required means of egress of the mall in a covered mall
building, occupant load factor (OLF) is not required to be less than ____
and shall not exceed ____. Answer: 30, 50.
◉ When a tenant space in an open or covered mall building has an
occupant load of ____ or more, not less than two means of egress shall
be provided? Answer: 50
◉ The maximum distance of travel from any point within a mall or a
covered mall building to an exit shall not exceed ____ feet? Answer: 200
◉ In a covered mall building, the minimum width of an exit passageway
or corridor from a mall shall be ____ inches? Answer: 66
◉ The aggregate clear egress width of the mall in either a covered or
open mall building shall be not less than _____ feet? Answer: 20
◉ Within each individual tenant space in a covered or open mall
building, the distance of travel from any point to an exit or entrance to
the mall shall be not greater than ____ feet? Answer: 200