100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Journeyman Electrician Practice Test Exam Question & Answers ( Latest 2025).docx

Rating
-
Sold
-
Pages
20
Grade
A+
Uploaded on
18-09-2025
Written in
2025/2026

Journeyman Electrician Practice Test Exam Question & Answers ( Latest 2025).docx

Institution
Push And Pull Factors Exa Question & Answer ( La
Module
Push and Pull Factors Exa Question & Answer ( La










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Push and Pull Factors Exa Question & Answer ( La
Module
Push and Pull Factors Exa Question & Answer ( La

Document information

Uploaded on
September 18, 2025
Number of pages
20
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Journeyman Electrician Practice Test
Exam Question & Answers ( Latest 2025)
Conductors with _____ marked on the insulation are NOT approved for
use in a wet location. - CORRECT ANSWERS ✔✔THHN


conductors with THHN insulation are approved for use in dry and damp
locations only and conductors with THWN, THHW, and THW insulation
are recognized for use in dry and wet locations.


Given: A one-family dwelling unit with a demand load of 200 amperes is
supplied with a 120/240 volt, single-phase, electrical system from the
local utility company. What is the MINIMUM size aluminum THW
conductors required for use as service-entrance conductors for this
residence? - CORRECT ANSWERS ✔✔4/0 AWG


one-family dwelling 120/240 volt, single-phase, service-entrance
conductors to be sized at an ampacity of not less than 83% of the
service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0
AWG THW aluminum conductors with an allowable ampacity of 180
amperes should be selected for this dwelling.


Where a 150 kVA, single-phase transformer having a secondary voltage
of 120/240 is installed at a multi-family dwelling, the full-load current
rating, in amperes, of the secondary is _____. - CORRECT ANSWERS
✔✔625 amperes

,Journeyman Electrician Practice Test
Exam Question & Answers ( Latest 2025)
To find the full-load current rating of the single-phase transformer
apply the single-phase current formula as shown:I = (150 kVA x 1000) /
240 volts = 15,000/240 = 625 amperes


Which one of the following listed circuit breakers is NOT a standard
ampere rating? - CORRECT ANSWERS ✔✔75 amperes


the standard ampere ratings for fuses and circuit breakers. A circuit
breaker with an ampere rating of 75 amperes is not a standard ampere
rating.


The MINIMUM length of free conductor to be left at each junction box
for the purpose of splicing conductors, or making connections to
illuminares or devices shall be _____ . - CORRECT ANSWERS ✔✔6
inches


free conductor is to be left at each junction box for splices or the
connection of luminaires or devices. The intent of this rule is to ensure
enough conductor slack for the terminal connections or splices to be
made easily.


In general, overhead service-drop conductors shall NOT be smaller than
_____. - CORRECT ANSWERS ✔✔8 AWG copper

, Journeyman Electrician Practice Test
Exam Question & Answers ( Latest 2025)
overhead service-drop conductors to be not smaller than 8 AWG
copper or 6 AWG aluminum or copper-clad aluminum. Do not get
service-drop conductors, the overhead conductors between the utility
electric supply system and the service point, confused with the service-
entrance conductors, the conductors from the service point from the
utility company to the service disconnecting means.


When a galvanized eye-bolt is to be used as the point of attachment for
an electrical service, the NEC requires the eye-bolt to be installed NOT
less than _____ above finished grade. - CORRECT ANSWERS ✔✔10
ft.


provide adequate vertical clearance of the conductors and prevent
physical damage to the conductors and prevent persons from making
accidental contact with the conductors which may create a shock
hazard or electrocution. In no case shall the point of attachment of the
service-drop conductors to be less than 10 ft. above finished grade.


Why is electrical continuity required for metallic conduit? - CORRECT
ANSWERS ✔✔To establish an effective ground-fault path and
facilitate the operation of the over-current protective device.


Electrical continuity is required for metallic conduit to establish an
effective ground-fault path and facilitate the operation of the
overcurrent protective device.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NatashaKate Florida A&M University
Follow You need to be logged in order to follow users or courses
Sold
16
Member since
1 year
Number of followers
0
Documents
2618
Last sold
1 month ago
Natashakate

1.0

1 reviews

5
0
4
0
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions