g g g g g g g g g g g g g g
answer>>
g
1.Evaporator
2. Condenser
3. Compressor
4. Auxillary Heat Exchanger g g
What is EPA 608 Type I certification? - answer>>Persons who maintain, service,
g g g g g g g g g g g
repair, or dispose of small appliances (containing 5 pounds of refrigerant (or
g g g g g g g g g g g g
less).
g
What is EPA 608 Type II certification? - answer>>Persons who maintain,
g g g g g g g g g g
service, repair, or dispose of high and very high pressure appliances. Except
g g g g g g g g g g g g
small appliances and motor vehicle air conditioning systems.
g g g g g g g g
What is EPA 608 Type III certification? - answer>>Persons who maintain,
g g g g g g g g g g
service, repair, or dispose of low pressure appliances.
g g g g g g g g
What is EPA 608 Universal certification? - answer>>Persons who maintain,
g g g g g g g g g
service, repair, or dispose of both low and high pressure equipment, as well as
g g g g g g g g g g g g g g
appliances.
g
HCFC's - answer>>HydroChloroFluoroCarbons
g g
,What are HydroChloroFluoroCarbons? - answer>>Commonly known as HCFC's,
g g g g g g g
they are a group of man-made compunds containing hydrogen, chlorine,
g g g g g g g g g g
fluorine, and carbon.
g g g
A recovery cylinder must not be filled more than
g g g g g g g g g % of it's capacity by
g g g g
weight? - answer>>80%
g g g
How should refrigerant cylinders be shipped? - answer>>Up-right with proper
g g g g g g g g g
DOT classification tags.
g g g
What oil MUST be used with ALL HFC's for HVAC/Refrigeration but will also work
g g g g g g g g g g g g g
with CFC's and HCFC's. - answer>>Polyolester
g g g g g g
HCFC's have very low atmospheric concentrations measured in parts per? -
g g g g g g g g g g
answer>>Trillion
g
All cooling systems containing more than 50 lbs. of refrigerant must be
g g g g g g g g g g g
repaired when the annual leak rate exceeds
g g ? - answer>>15%
g g g g g g g
Medium-pressure appliance can use which of the following refrigerants: g g g g g g g g
R-12
R-22
g
R-
g
123
R-11 - answer>>R-12
g g
,To Convert From Inches of Mercury To Millimeters of Mercury Absolute
g g g g g g g g g g g
the Inches of Mercury by 25.4 and _____ the result from 760
g g g g g g g g g g
Divide, Subract g
g Multiply, Add g
g Multiply, Subtract g
Divide, Add - answer>>Multiply, Subtract
g g g g
When the refrigerant is put back into a Type III chiller, following recovery and
g g g g g g g g g g g g g
system repair, where is it added? - answer>>The charging valve on the
g g g g g g g g g g g g
evaporator.
g
What method is used to find suspected water tube leaks in chillers? -
g g g g g g g g g g g g
answer>>Hydrostatic (tube) test
g g g
What temperature should be attained when removing oil from a low pressure
g g g g g g g g g g g
system to ensure a lower level of refrigerants in the oil? - answer>>130-
g g g g g g g g g g g g g
Degrees F
g g
The typical design burst pressure for a rupture disc is what? - answer>>15 PSIG
g g g g g g g g g g g g g
Excessive moisture collection in the purge unit can indicate what? -
g g g g g g g g g g
answer>>Tube Leakage
g g
, Vacuum pumps need to be capable of pulling what level of vacuum? -
g g g g g g g g g g g g
answer>>500 microns
g g
All refrigeration systems containing more than 50 lbs. of refrigerant must be
g g g g g g g g g g g
repaired when the annual leak rate exceeds
g g ? - answer>>35%g g g g g g g
The most efficient method of leak checking a charged low-pressure system is to
g g g g g g g g g g g g
use? - answer>>Controlled hot water or heater blankets.
g g g g g g g g
Systems with open drive compressors are prone to leak where? - answer>>At
g g g g g g g g g g g
the shaft seal.
g g g
What does ASHRAE standard 15 require? - answer>>A refrigerant monitor that
g g g g g g g g g g
will sound and alarm and automatically start a ventilation system in
g g g g g g g g g g g
equipment rooms before the refrigerant concentration reaches the TLV-
g g g g g g g g g
TWA.
g
TLV-TWA - answer>>Threshold Limit Value, Time Weighted Average
g g g g g g g
A-1 Group Refrigerants only require what? - answer>>Oxygen Deprivation
g g g g g g g g
Sensor
g
All "B" rated refrigerants require what? - answer>>"Refrigerant Specific"
g g g g g g g g
Mechanical Room Sensor.
g g g