COMMON PATH OF EGRESS TRAVEL Correct answer-The portion of the exit access [access to an
exit] that must be traversed BEFORE two separate and distinct paths to travel to two exits are
available.
TRAVEL DISTANCE Correct answer-The distance measured from the most remote point within a
story to the entrance to an exit along the natural and unobstructed path of egress travel.
The following four items must be 1-HR rated: Correct answer-1) Demising partitions between
tenant spaces (2.1);
2) Partitions along public corridor (2.2);
3) Partitions that demise an Assembly Occupancy of 750sf or greater (2.3);
4) Storage rooms greater than 100sf (2.5)
Doors for 1 hour partitions require: Correct answer-20-min and be self-closing
Glazing in fire rated partitions, doors, or sidelines may not exceed: Correct answer-240 sq. in.
Audio/visual fire signal devices are required in each of the following rooms: Correct answer-
Restroom;
Hallway;
Lobby;
and General Assembly area
Audio/visual fire signal devices mist be visible from: Correct answer-Every location within the
room.
Audio/visual fire signal devices must be mounted between: Correct answer-6' - 8" and 7' - 6"
Minimum number of fire extinguishers are: Correct answer-1 per 3,000 square feet
Fire extinguishers must be located no more than ____ft from the furthest occupant. Correct
answer-75 ft
Smoke detector coverage must include all: Correct answer-Rooms;
Corridors; and
Storage Areas
The means of egress must have a ceiling height not less than ____. Correct answer-7' - 6"
Objects protruding from the ceiling must provide a minimum head clearance of _____. Including any
corridor, aisle, or passageway. Correct answer-6' - 8"
True or False: Protruding objects must not reduce the minimum clear width of exit routes. Correct
answer-True.