100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

HVAC NATE Heat Pump Exam 2025 Questions and Answers

Rating
-
Sold
-
Pages
22
Grade
A+
Uploaded on
20-05-2025
Written in
2024/2025

HVAC NATE Heat Pump Exam 2025 Questions and Answers

Institution
NATE
Module
NATE










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NATE
Module
NATE

Document information

Uploaded on
May 20, 2025
Number of pages
22
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

HVAC NATE Heat Pump Exam 2025
Questions and Answers


On an R-22 system, line diameters and lengths are typically specified for a vapor pressure drop that

does not exceed what? - ANSWER✔✔-6-7PSI or 6F


What is the primary purpose of using flux when soldering copper or brass parts? - ANSWER✔✔-

Prevent Oxidation


The water that results from a defrost cycle of an air to air heat pump(runoff) must? - ANSWER✔✔-

Drain off and away from the outdoor coil.


Why must the runoff be drained off and away from the outdoor coil? - ANSWER✔✔-Excessive ice

can build up on the bottom of the coil and can reduce capacity.

What is the component that reduces sound transmission and prevents water leaks of a package heat

pump installed on a roof? - ANSWER✔✔-Curb Gasket


Why do you need to add a control for a heat pump indoor coil that is installed on a fossil fuel

furnace? - ANSWER✔✔-So the heat pump and furnace do not operate at the same time in normal

heating.




FOR STUDY PURPOSES ONLY COPYRIGHT © 2025 ALL RIGHTS RESERVED 1

,What happens when you energize a hermetic refrigeration compressor and the system is in a deep

vacuum? - ANSWER✔✔-Motor windings could become damaged.


What needs to happen in order to consider an evacuation to be complete? - ANSWER✔✔-System

should be evacuated to a vacuum of 500 Microns or below.

A system is supplied from the factory with charge for a 15 foot line set. The data plate shows the

required system charge to be 5 pounds 10 ounces. The line set uses a 3/8 inch liquid line and is 25

feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigerant to be added for

each added foot of refrigerant line length. How much refrigerant is needed to completely charge the

system? - ANSWER✔✔-6lbs


Where are drive slips typically installed? - ANSWER✔✔-On the shorter sides of rectangular duct.


What is a necessary check to properly set a heat anticipator? - ANSWER✔✔-Heating control circuit

amperage

draw.

A heat pump operating in normal ice free conditions maintains a certain temperature difference

between the outdoor coil temperature and the surrounding outdoor ambient. What is this

temperature referred to as? - ANSWER✔✔-Coil TD.


What is the smallest refrigerant leak that an electronic leak detector should be capable of sensing? -

ANSWER✔✔-.o5oz per year.


When checking the pressures in an operating system with a manifold gauge set, will refrigerant oil in

a hose will have an effect on the gauge? - ANSWER✔✔-No



FOR STUDY PURPOSES ONLY COPYRIGHT © 2025 ALL RIGHTS RESERVED 2

, What is the absolute pressure at sea level if a gauge pressure is 35 psig? - ANSWER✔✔-49.7psia


100,000 BTUH output furnace.

Return air temp is 65F.

Supply air is 135F.


What is the CFM? - ANSWER✔✔-1323CFM


What is the best method of repair when a residential supply diffuser is noisy because of a loose

vane? - ANSWER✔✔-Replace the diffuser.


When performing preventive maintenance on a heat pump what should the technician check and

why? - ANSWER✔✔-Outdoor fan. To be certain it runs freely with no binding.


What is the effect of 170 volts supplied to a 208/230 volt compressor? - ANSWER✔✔-Would

cause the current to increase and the motor may trip on overload.

On a service call for a cooling problem with a heat pump, your inspections find a liquid line that has

condensation on it. What is most likely to cause this? - ANSWER✔✔-Restriction in the liquid line.


What is a reason for cool air complaints when a heat pump is operating in the heating cycle? -

ANSWER✔✔-Excessive supply air velocities.


The following measurements are recorded on an operating heat pump system. The heat pump is

operating with the compressor only with no auxiliary heat:




• Heat pump only supply air temperature 92°F



FOR STUDY PURPOSES ONLY COPYRIGHT © 2025 ALL RIGHTS RESERVED 3
£9.52
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
Follow You need to be logged in order to follow users or courses
Sold
1093
Member since
2 year
Number of followers
482
Documents
33057
Last sold
5 days ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reviews

5
95
4
38
3
54
2
20
1
31

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions