100%CORRECT!!
HOW MUCH TIME IS REQUIRED TO COMPLETE THE EXAM - Answer 4
WHICH OF THE FOLLOWING ARE CHARACTERISTIC OF SLEEP IN THE
ELDERLY PERSON - Answer A DECREASED REM LATENCY
WHAT IS THE RECOMMENDED MAXIMUM IPAP-EPAP DIFFERENTIAL - Answer
10 CM H20
IF PRESENTED WITH A QUESTION ABOUT CPAP/BIPAP TITRATION
PROTOCOLS, WHAT IS THE BEST SOURCE FOR THE CORRECT ANSWER -
Answer AASM CLINICAL GUIDELINES
HOW MANY PATHWAYS TO EXAM ELIGIBILITY ARE THERE - Answer 4
WHICH IS THE ONLY PATHWAY TO EXAM ELIGIBILITY THAT DOES NOT
REQUIRE PAID PSG EXPERIENCE - Answer PATHWAY 3
IN WHAT MONTH WILL ON DEMAND TESTING BEGIN - Answer JUNE 2010
FOR WHAT TIME PERIOD IS THE EXAM AUTHORIZATION VALID - Answer 1
YEAR
HOW MANY DOMAINS ARE IN THE EXAM - Answer 5
IF THE MEASUREMENT FROM NASION TO INION IS 36CM. WHAT IS THE
DISTANCE FROM NASION TO FPZ - Answer 3.6CM
IF THE MEASUREMENT FROM NASION TO INION IS 30 CM
WHAT IS THE DISTANCE FROM FZ TO CZ - Answer 6CM
IF THE MEASUREMENT FROM LEFT PRE-A TO RIGHT PRE-A IS 35CM WHAT IS
THE DISTANCE FROM C3 TO T3 - Answer 7CM
IF THE MEASUREMENT AROUND TO HEAD IS 60CM. WHAT IS THE DISTANCE
BETWEEN FP1 TO FP2 - Answer 6CM
IF THE DISTANCE BETWEEN FP1 AND O1, CROSSING THROUGH C3 IS 40CM.
WHAT IS THE DISTANCE BETWEEN FP1 AND F3 - Answer 10CM
IF THE MEASUREMENT FROM F7 TO F8, THROUGH FZ IS 24CM. WHAT IS THE
DISTANCE FORM F7 TO F3 - Answer 6CM
IF THE UNIT OF RESISTANCE IS OHMS, WHAT IS ANOTHER WAY TO WRITE
5000 OHMS - Answer 5 KILOHMS
EYE LEADS PLACED AT THE OUTER CANTHUS OF EACH EYE, ABOVE THE
OUTER CANTHUS ON THE RIGHT, AND BELOW THE OUTER CANTHUS ON
, RPSGT EXAM VERIFIED
100%CORRECT!!
THE LEFT, WILL RECORD - Answer HORIZONTAL AND VERTICAL EYE
MOVEMENT
WHAT ARE DC AMPLIFIERS USED FOR IN THE PSG - Answer OXIMETRY
ACCORDING TO THE AASM SCORING MANUAL, WHAT IS THE FREQUENCY
RANGE FOR EYE BLINKS - Answer 0.5-2 HZ
WHAT IS THE FREQUENCY OF AC CURRENT IN THE UNITED STATES - Answer
60 HZ
WHICH OF THE FOLLOWING IS A PROPERTY OF THE EYE THAT ENABLES
EOG RECORDING - Answer THE CORNEA IS ELECTRO-POSITIVE WITH
RESPECT TO THE RETINA
WHICH OF THE FOLLOWING ARE PROCESSED THROUGH A DC AMPLIFIER IN
POLYSOMNOGRAPHY - Answer OXIMETRY
IF G1 INPUT IS +35UV, AND G2 IS +10UV, AND THE SENSITIVITY IS 7UV/MM,
WHAT IS THE RESULTING DEFLECTION - Answer 3.6MM
A LOW PASS FILTER - Answer REDUCES THE AMPLITUDE OF HIGH
FREQUENCY ACTIVITY
A LOW FREQUENCY FILTER - Answer REDUCES THE AMPLITUDE OF LOW
FREQUENCY ACTIVITY
ACCORDING TO AASM WHICH OF THE FOLLOWING IS THE RECOMMENDED
HIGH FREQUENCY FILTER SETTING FOR EMG - Answer 100 HZ
A LOW PASS FILTER SETTING OF 1 HZ WOULD - Answer REDUCE THE
AMPLITUDE OF SLOW WAVES
A TECH IS SCORING A PSG AFER THE PATIENT HAS LEFT. MUSCLE
ARTIFACT IN THE EEG CHANNEL IS OBSCURING SLEEP ONSET. WHICH OF
THE FOLLOWING FILTERS MAY BE TEMPORARILY ADJUSTED TO MINIMIZE
MUSCLE ARTIFACT. - Answer HFF
ACCORDING TO AASM WHAT IS THE RECOMMENDED LFF SETTING FOR THE
RESPIRATORY CHANNEL - Answer 0.1 HZ
ACCORDING TO AASM WHAT IS THE RECOMMENDED HIGH PASS FILTER
SETTING FOR EEG - Answer 0.3 HZ
STANDARD CALIBRATION FOR DC VOLTAGE APPLIED IS - Answer -50UV