Electrical level 3 commercial electrical
services, Branch-Circuit, Feeder, and
Service Design, Grounding and Bonding Level
II, Load Calculations- Branch and Feeder
Circuits ACTUAL EXAM 2025-2026 COMPLETE
QUESTIONS AND CORRECT DETAILED ANSWERS ||
100% GUARANTEED PASS
<LATEST VERSION>
1. Article 90 - ANSWER ✓ Introduction
2. Article 100 - ANSWER ✓ Definitions
3. Article 110.26 - ANSWER ✓ Working space
4. Article 210 - ANSWER ✓ Branch circuits
5. Article 210.7 - ANSWER ✓ Gfci protection for personal
6. Article 210.50 - ANSWER ✓ Required outlets
7. Article 215 - ANSWER ✓ Feeders
8. Article 220 - ANSWER ✓ Branch circuit, feeder and service calculations
9. Article T225.55 - ANSWER ✓ Range demand factors
,10.Article 225 - ANSWER ✓ Outside branch circuits and feeders
11.Article 230 - ANSWER ✓ Services
12.Article 240 - ANSWER ✓ Over Current protection
13.Article 240.21 - ANSWER ✓ Taps and x fmr secondary conductor
14.Article 250 - ANSWER ✓ Grounding and bonding
15.Article 250.52 - ANSWER ✓ Grounding electrodes
16.Article 250.66 - ANSWER ✓ Grounding electrode conductor
17.Article T250.122 - ANSWER ✓ Equipment grounding conductor
18.Article 300 - ANSWER ✓ General requirements for wiring methods and
materials
19.Article T300.5 - ANSWER ✓ Minimum cover requirements
20.Using NEC Section 250-8, identify five methods of making connections. -
ANSWER ✓ 1. Listed Pressures Connectors
2. Terminal Bars
3. Pressure Connectors Listed As Ground and Bonding Equipment
4. Exothermic Welding
5. Machine screw-type fasteners that engage not less than two threads or are
screwed with nuts
21.Underground service is simpler to troubleshoot and repair than overhead
service? (True or False) - ANSWER ✓ Relative to underground service,
overhead electrical service is simpler to troubleshoot and repair and is the
easier option when running electricity across roadways, waterways, and
right-of-ways.
,22.In NEC, Table _____ provides the sizing of grounding electrode conductors.
- ANSWER ✓ NEC 250.66 provides the sizing of grounding electrode
conductors
23.Describe the process for bonding three 200-amp disconnects to make a
proper grounding system. - ANSWER ✓ To make a proper grounding
system using three 200-amp disconnects, use a ground wire of sufficient size
to go from panel to panel with a lug, screw, or ground bar, if provided.
24.In terms of AWG, what is the minimum grounding conductor size
permitted? - ANSWER ✓ The smallest grounding conductor permitted is 6
awg or larger.
25.The way to ground a transformer in a commercial building is to place a
grounding rod inside the building? (True or False) - ANSWER ✓ False, The
way to ground a transformer in a commercial building is to place a
grounding rod outside or beneath the building.
26.Why do stoves require a four-wire system? - ANSWER ✓ Two hots are
needed to operate the stove neutral. The timers and clocks can serve as
ground for tripping mechanism.
27.Why do dryers require a four-wire system? - ANSWER ✓ Two hots are
needed to operate the heater neutral. The timers can serve as ground for
tripping mechanism.
28.Air-conditioning units, hot water heaters, and baseboard heat require a four-
wire system? (True or False) - ANSWER ✓ False, a A/C unit needs only
220 and a ground to complete the circuit.
29.Which of the following NEC sections outlines which air-conditioning
systems requires no grounding? - ANSWER ✓ NEC 250.114
30.Explain where and why isolated systems are used. - ANSWER ✓ Isolated
systems are used in healthcare facilities due to explosive gases.
, 31.Electricians should put grounded conductors on yellow reciprocal screws?
(True or False) - ANSWER ✓ False, grounding conuctors belong on the
green screws.
32.On a 200-amp service, the electrician should use _____ or _____ size
grounded conductor in the service cable. - ANSWER ✓ 2/0 or 4/0
33.When using 500 MCM, _____ or ______ size ground wire is appropriate on
a 400-amp service. - ANSWER ✓ 350MCM or 400MCM
34.Name a common application for high impedance grounding. - ANSWER ✓
High impedance grounding is used for grounding radio towers. NEC
250.20(E)
35.What is the proper way to test conduit for proper grounding? - ANSWER ✓
To test conduit for proper grounding, check ohms or use 120V receptacle
and touch to ground to check for voltage.
36.How does an NEC violation affect the occupancy of an existing installation?
- ANSWER ✓ Per NEC 90.4, 510.2, and various local codes, occupancy is
permitted in the event of a code violation as long as the occupancy remains
unchanged and no hazardous condition exists.
37.The maximum operating temperature of type FFH-2 fixture wiring is? -
ANSWER ✓ Per NEC 402.3, FFH-2 fixture wiring is useable up to 75
degrees C
38.NEC Article _____ addresses bonding requirements in healthcare facilities. -
ANSWER ✓ NEC Article 517
39.FMT conductors are appropriate for battery storage areas. (True or False) -
ANSWER ✓ False, Per 360.12, FMT is disallowed from battery storage
areas
40.A circuit that cannont cause a fire in a hazardous condition is called a(n)
_____ system. - ANSWER ✓ An Intrinsically Safe System.