Answers
Design for modularity
Design for simplicity
Design for standards adherence
Design for security - ANSWERSSelect one or more of the following as valid data center
design principles:
Familiarity with your company and products is not typically a requirement. -
ANSWERSSelect a category from the list below that should not typically be included as
requirements when evaluating external hosting providers?
Availability
Data Archiving and Retention
Security - ANSWERSSelect one or more valid non-functional requirements of the Data
Center:
An adequate budget and an abundant pool of qualified employees - ANSWERSWhich
of the following is not considered a data center project constraint?
T/F: A company's Data Center should always be required to host any application
irrespective of the technology upon which it is built. - ANSWERSFalse
Which of the following is not typically a category for defining current Data Center
Requirements? - ANSWERSPast requirements
It is reasonable to have a requirement for a Data Center hosting provider around the
area of Service Level Agreements and Objectives. - ANSWERSTrue
, Which of the following Data Center Tier levels according to the Uptime Institute meet all
of the following criteria : 1. 2 simultaneously active distribution paths, 2. Continuous
Cooling (Class A), and 3) is concurrently maintainable, fault tolerant, has N active
capacity components to support IT load, and provides compartmentalization. -
ANSWERSTier 4
Select one of the following as not an essential design criteria for the data center. -
ANSWERSEquipment such as forklifts and pallet jacks
Which of the following are not part of the TIA-942 scope for Data Centers? -
ANSWERSLocal regulations
Which of the following technologies are examples of recent trends in Data Centers? -
ANSWERSAll the above
According to the textbook in chapter 3, the Bahnhof Data Center in Sweden makes their
customers secure about the physical security of the DC because it is built within a
former nuclear bunker and is conveniently located centrally in Stockholm. -
ANSWERSTrue
Which of the following areas are examples where consolidation in the Data Center
occurs? - ANSWERSAll of the answers are correct and have been a focus in
consolidation efforts.
Which one of the following is not a best practices design principle for the Data Center? -
ANSWERSDesign for rigidity
Which Data Center tier level below most correctly describes a Data Center with multiple
active distribution paths? - ANSWERSTier 3
The component in the Data Center which typically consumes the most power
proportionally is _________. - ANSWERSCooling is the most energy intensive
component - consuming approximately 38% of the power.
Which of the following metrics is derived by taking the IT equipment power divided by
total facility power? - ANSWERSDCIE
Select the following area(s) that are valid forms of network virtualization in the Data
Center. - ANSWERSVirtual LAN (VLAN)
Virtual Private Network (VPN)
Out-of-band Network
T/F: The value of an efficiency metric in a Data Center should not vary during the
course of a day or week. - ANSWERSFalse