100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

ARRT MRI Exam Prep (Latest 2024/ 2025 Update) Questions and Verified Answers| Grade A| 100% Correct

Rating
-
Sold
-
Pages
129
Grade
A+
Uploaded on
13-12-2024
Written in
2024/2025

ARRT MRI Exam Prep (Latest 2024/ 2025 Update) Questions and Verified Answers| Grade A| 100% Correct Q: From a resting state in which the fully relaxed net magnetization is aligned along the longitudinal direction, what would the application of a single 45 RF pulse result in? a. equal amounts of transverse magnetization and longitudinal magnetization b. greater longitudinal magnetization than transverse magnetization c. greater transverse magnetization than longitudinal magnetization d. zero longitudinal magnetization Answer:: a. Q: Which of the following if the definition of T2 relaxation? a. the time at which the transverse magnetization has decayed to 63% of its full value b. the time at which the transverse magnetization has decayed to 37% of its full value Answer:: b. Q: By increasing the TE from 80ms to 120ms on a spin-echo pulse sequence, which of the following is the expected result? a. better tissue contrast based on the tissues' T1 characteristics b. a stronger signal in the MR echo c. fewer protons would experience spin-spin interactions d. better tissue contrast based on the tissues' T2 characteristics Answer:: d. Q: If six successive 180 RF pulses are applied, following a 90 RF pulse, how many echoes will be formed? a. one b. two c. six d. eight Answer:: c. Q: If the six successive 180 RF pulses are applied, following a 90 RF pulse, echo ____ will contain the greatest signal? a. one b. three c. five d. six Answer:: a. Q: Using a spin-echo pulse sequence which generates two echoes, imagine a hypothetical tissue in which protons never experience spin-spin interactions. How does the signal from the first echo compare to the signal from the second echo? a. its frequency is higher b. its frequency is lower c. its the same size d. it is smaller in size Answer:: c. Q: What is the time from the 180 RF pulse to the echo? a. TE b. TR c. 2.0 x TE d. 0.5 x TE Answer:: d. TE/2 TAU Q: Which of the following dephasing mechanisms is NOT rephased by a 180 RF pulse? a. magnetic susceptibility b. phase effects of a chemical shift c. spin-spin interactions d. magnetic field inhomogeneities Answer:: c. Q: Which of the following parameters controls the amount of contrast seen in an image due to T2 relaxation? a. TI b. TR c. TM d. TE Answer:: d. Q: The effect of an IV. administered paramagnetic contrast agent used in MRI is a shortening of a T1 relaxation time of the protons within any perfused tissue. A vascular lesion would appear ____ on a T1-W contrast-enhanced image as compared to its appearance on a T1-W unenhanced image. a. the same b. darker c. as a signal void d. brighter Answer:: d. Q: In a given MR system, the magnetization of protons within the patient precesses at 63.83MHz. Without the interference of any other system component, what is the expected result if the RF energy is applied at a frequency of 63.83 MHz? a. only the patient's protons in a sagittal slice will be disturbed by the external energy b. all of the patient's protons within range of the transmitting antenna will be disturbed by the external energy c. none of the patient's protons would be disturbed by the external energy d. only the patient's protons in a transverse slice will be disturbed by the external energy Answer:: b. Q: If the field strength experienced by a patient within an MR magnet is increased, the precessional frequency of the magnetization of the patient's protons will: a. increase b. reverse its spin direction c. remain unaffected d. decrease Answer:: a. Q: The energy used to form MR images is ____ the patient's tissues. a. attenuated by b. magnified by c. reflected off of d. released from

Show more Read less
Institution
ARRT MRI
Module
ARRT MRI

Content preview

ARRTlMRIlExamlPrepl(LatestlUpdate)
lQuestionslandlVerifiedlAnswers|lGradelA|l
100%lCorrect

Q:lFromlalrestinglstatelinlwhichlthelfullylrelaxedlnetlmagnetizationlislalignedlalonglthellongit
udinalldirection,lwhatlwouldlthelapplicationloflalsinglel45lRFlpulselresultlin?

a.lequallamountslofltransverselmagnetizationlandllongitudinallmagnetization
b.lgreaterllongitudinallmagnetizationlthanltransverselmagnetization
c.lgreaterltransverselmagnetizationlthanllongitudinallmagnetization
d.lzerollongitudinallmagnetization


Answer::
a.



Q:lWhichloflthelfollowinglifltheldefinitionloflT2lrelaxation?
a.ltheltimelatlwhichltheltransverselmagnetizationlhasldecayedltol63%loflitslfulllvalue
b.ltheltimelatlwhichltheltransverselmagnetizationlhasldecayedltol37%loflitslfulllvalue


Answer::
b.



Q:lBylincreasinglthelTElfroml80msltol120mslonlalspin-
echolpulselsequence,lwhichloflthelfollowinglislthelexpectedlresult?

a.lbetterltissuelcontrastlbasedlonltheltissues'lT1lcharacteristics
b.lalstrongerlsignallinlthelMRlecho
c.lfewerlprotonslwouldlexperiencelspin-spinlinteractions
d.lbetterltissuelcontrastlbasedlonltheltissues'lT2lcharacteristics


Answer::
d.

,Q:lIflsixlsuccessivel180lRFlpulseslarelapplied,lfollowinglal90lRFlpulse,lhowlmanylechoeslwil
llbelformed?

a.lone
b.ltwo
c.lsix
d.leight


Answer::
c.



Q:lIflthelsixlsuccessivel180lRFlpulseslarelapplied,lfollowinglal90lRFlpulse,lechol____lwilllco
ntainlthelgreatestlsignal?

a.lone
b.lthree
c.lfive
d.lsix


Answer::
a.



Q:lUsinglalspin-
echolpulselsequencelwhichlgeneratesltwolechoes,limaginelalhypotheticalltissuelinlwhichlproton
slneverlexperiencelspin-
spinlinteractions.lHowldoeslthelsignallfromlthelfirstlecholcompareltolthelsignallfromlthelsecond
lecho?

a.litslfrequencylislhigher
b.litslfrequencylisllower
c.litslthelsamelsize
d.litlislsmallerlinlsize


Answer::
c.

,Q:lWhatlisltheltimelfromlthel180lRFlpulseltolthelecho?
a.lTE
b.lTR
c.l2.0lxlTE
d.l0.5lxlTE


Answer::
d.l

TE/2
TAU



Q:lWhichloflthelfollowingldephasinglmechanismslislNOTlrephasedlbylal180lRFlpulse?
a.lmagneticlsusceptibility
b.lphaseleffectsloflalchemicallshift
c.lspin-spinlinteractions
d.lmagneticlfieldlinhomogeneities


Answer::
c.



Q:lWhichloflthelfollowinglparameterslcontrolslthelamountloflcontrastlseenlinlanlimagelduelto
lT2lrelaxation?

a.lTI
b.lTR
c.lTM
d.lTE


Answer::
d.

, Q:lTheleffectloflanlIV.ladministeredlparamagneticlcontrastlagentlusedlinlMRIlislalshorteningl
oflalT1lrelaxationltimeloflthelprotonslwithinlanylperfusedltissue.lAlvascularllesionlwouldlappea
rl____lonlalT1-Wlcontrast-enhancedlimagelaslcomparedltolitslappearancelonlalT1-
Wlunenhancedlimage.

a.lthelsame
b.ldarker
c.laslalsignallvoid
d.lbrighter


Answer::
d.



Q:lInlalgivenlMRlsystem,lthelmagnetizationloflprotonslwithinlthelpatientlprecesseslatl63.83M
Hz.lWithoutlthelinterferenceloflanylotherlsystemlcomponent,lwhatlislthelexpectedlresultliflthel
RFlenergylislappliedlatlalfrequencylofl63.83lMHz?

a.lonlylthelpatient'slprotonslinlalsagittallslicelwilllbeldisturbedlbylthelexternallenergy
b.lallloflthelpatient'slprotonslwithinlrangelofltheltransmittinglantennalwilllbeldisturbedlbylthelex
ternallenergy
c.lnoneloflthelpatient'slprotonslwouldlbeldisturbedlbylthelexternallenergy
d.lonlylthelpatient'slprotonslinlaltransverselslicelwilllbeldisturbedlbylthelexternallenergy


Answer::
b.



Q:lIflthelfieldlstrengthlexperiencedlbylalpatientlwithinlanlMRlmagnetlislincreased,lthelprecess
ionallfrequencyloflthelmagnetizationloflthelpatient'slprotonslwill:

a.lincrease
b.lreverselitslspinldirection
c.lremainlunaffected
d.ldecrease


Answer::
a.

Written for

Institution
ARRT MRI
Module
ARRT MRI

Document information

Uploaded on
December 13, 2024
Number of pages
129
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

£9.05
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
nurse_steph Rasmussen College
Follow You need to be logged in order to follow users or courses
Sold
9488
Member since
5 year
Number of followers
5145
Documents
7608
Last sold
15 hours ago
Exams, Study guides, Reviews, Notes

All study solutions.

3.9

1703 reviews

5
853
4
303
3
263
2
80
1
204

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions